Installation Instructions

INSTALLING THE ZONELINE

1INSTALL THE WALL CASE AND

EXTERIOR GRILLE

The RAB71 series or RAB77 wall case must be properly installed per instructions packed with the case.

Remove the corrugated stiffener and the outdoor protective panel. Use the slit in the outdoor panel as a handhold and push out.

Protective

 

 

 

Slit

 

 

panel

 

 

 

 

Stiffener

Install the exterior grille from the room side following instructions packed with the grille.

Insulated Wall Case

This unit is designed to be installed in a GE plastic or an insulated steel wall case. This minimizes condensation from forming on the room side of the case.

The RAB71 series wall cases are insulated. Insulation kit RAK901L is available for use with RAB77 or existing uninsulated wall cases when needed.

NOTE: For installation with a subbase or duct adapter, see the instructions packed with those kits.

2PREPARE THE UNIT

Carefully remove shipping tape and foam shipping blocks from the room cabinet, compressor and vent door. There may be multiple blocks and pieces of shipping tape that need to be removed.

Shipping tape (Locations may vary)

Remove the room cabinet by pulling it out at the bottom to release it (1), then lift it up to clear the rail along the unit top (2).

If vent door is to be operational, remove shipping screws from the front side of the vent door, if present.

Remove two shipping screws

17

Page 17
Image 17
GE 2900, 3900 installation instructions Installing the Zoneline, Install the Wall Case Exterior Grille, Prepare the Unit