2.2.4Permeate Outlet Connection

Install the CIP valve on the permeate outlet tee. The pure water (permeate) should be transported to the point of use via non-corroding-type tubing, pipe, or hose. Examples are: food-grade flexible nylon tubing, stainless steel tubing, or PVC hose. The permeate outlet is 1-inch FNPT.

2.3Electrical

The DLX and ECN E-Series models are supplied with a single-phase, 110 VAC 60 Hz or 220 VAC 50 Hz control circuit and 8-foot cord which plugs into a three-prong grounded receptacle. For 220 VAC, 50 Hz units, plug must be customer-supplied. A 20 amp dedicated service circuit is required for proper operation.

For each model, the motor is wired at the factory to an overload protection magnetic motor starter which is controlled by a panel-mounted manual switch.

The electrical system control circuit is separate from the motor voltage. Therefore, electrical wiring required in the field needs two supply voltages, the control circuit voltage and a separate three-phase motor voltage. All field wiring must comply with applicable local and national electric codes.

2.3.1Economy Electrical System

STEPS

1.Connect the control circuit power cord to 115 VAC, 60 Hz, or 220 VAC, 50 Hz, single-phase power.

2.Connect the magnetic motor starter 230/460 VAC or 220/380 VAC, three-phase power to match the motor voltage and phase. Check the tag (located on the motor starter) that indicates the factory wiring. A separate, fused disconnect for the motor wiring is required, with proper protection for the Hp and amp draw of the motor.

Refer to drawing #1164309 for the ECN electrical diagram. The ECN circuit has a timing relay for delayed machine shutdown.

2.3.2Deluxe Electrical System

STEPS

1.Connect the control circuit power cord to 115 VAC, 60 Hz, or 230 VAC, 50 Hz, single-phase power.

2.Connect the magnetic motor starter 230/460 VAC or 220/380 VAC, three-phase power to match the motor voltage and phase. Check the tag (located on the motor starter) that indicates the factory wiring. A separate, fused disconnect for the motor wiring is required, with proper protection for the Hp and amp draw of the motor.

11