Installation Instructions

1INSTALLING THE WATER LINE (CONT.)
7CONNECT THE TUBING TO THE REFRIGERATOR
NOTES:

Before making the connection to the refrigerator, be sure the refrigerator power cord is not plugged into the wall outlet.

We recommend installing a water filter if your water supply has sand or particles that could clog the screen of the refrigerator’s water valve. Install it in the water line near the refrigerator. If using GE SmartConnectRefrigerator Tubing kit, you will need an additional tube (WX08X10002) to connect the filter. Do not cut plastic tube to install filter.

Remove the access cover.

Remove the plastic flexible cap from the water valve (refrigerator connection).

Place the compression nut and ferrule (sleeve) onto the end of the tubing as shown. On GE SmartConnectRefrigerator Tubing kit,

the nuts are already assembled to the tubing.

Insert the end of the tubing into the water valve connection as far as possible. While holding the tubing, tighten the fitting.

For plastic tubing from a GE SmartConnectRefrigerator Tubing kit, insert the molded end of the tubing into the shutoff valve and tighten compression nut until it is hand tight, then tighten one additional turn with a wrench. Overtightening may cause leaks.

Fasten the tubing into the clamp provided

to hold it in a vertical position. You may need to pry open the clamp.

1/4Copper

Tubing Clamp

Tubing

 

 

1/4Compression

 

Nut

 

Ferrule (sleeve)

 

SmartConnect

Refrigerator Connection

Tubing

 

Reattach the access cover.

8TURN THE WATER

ON AT THE

SHUTOFF VALVE

Tighten any connections that leak.

9PLUG IN THE REFRIGERATOR

Arrange the coil of tubing so that it does not vibrate against the back of the refrigerator or against the wall. Push the refrigerator back to the wall.

10 START THE ICEMAKER

On power switch models, set the icemaker power switch to the l (on) position. On feeler arm models, move the feeler arm to the ON (down) position. The icemaker will not begin to operate until it reaches its operating temperature of 15°F (–9°C) or below. It will then begin operation automatically.

Power switch

Power switch model

Feeler Arm in the

STOP (up) position

Feeler Arm in

the ON (down) position

Feeler arm model

NOTE: In lower water pressure conditions, the water valve may turn on up to 3 times to deliver enough water to the icemaker.

12