QT060
OPERATING DATA
|
|
| QT060 |
|
kW RATING |
|
| 60 |
|
|
|
|
|
|
ENGINE SIZE |
|
| 2.4 Liter Inline 4 |
|
|
|
|
|
|
GENERATOR OUTPUT VOLTAGE/KW - 60Hz |
| KW | AMP | CB Size |
120/208V, |
| 60 | 208 | 250 |
120/240V, |
| 60 | 180 | 200 |
277/480V, |
| 60 | 90 | 100 |
|
|
|
|
|
GENERATOR LOCKED ROTOR KVA |
|
|
|
|
AVAILABLE @ VOLTAGE DIP OF 35% |
|
|
|
|
Single phase or 208/240 |
|
| 120 |
|
480V |
|
| 141 |
|
|
|
| ||
ENGINE FUEL CONSUMPTION (Natural Gas) (Propane) | Natural Gas | Propane | ||
|
| (ft3/hr.) | (gal/hr.) | cu ft/hr |
Exercise cycle |
| 123 | 1.34 | 49.3 |
25% of rated load |
| 267 | 2.7 | 101 |
50% of rated load |
| 483 | 5.0 | 183 |
75% of rated load |
| 672 | 7.0 | 255 |
100% of rated load |
| 862 | 9.0 | 327 |
|
|
|
|
|
ENGINE COOLING |
|
|
|
|
Air flow (inlet air including alternator and combustion air) | ft3/min. |
| 3,280 |
|
System coolant capacity | US gal. |
| 2.5 |
|
Heat rejection to coolant | BTU/hr. |
| 270,000 |
|
Max. operating air temp. on radiator | °C (°F) |
| 60 (150) |
|
Max. ambient temperature | °C (°F) |
| 50 (140) |
|
|
|
|
|
|
COMBUSTION AIR REQUIREMENTS |
|
|
|
|
Flow at rated power 60 Hz | cfm |
| 180 |
|
|
|
|
|
|
SOUND EMISSIONS IN DBA |
|
|
|
|
Exercising at 7 meters |
|
| 65 |
|
Normal operation at 7 meters |
|
| 72 |
|
|
|
|
|
|
EXHAUST |
|
|
|
|
Exhaust flow at rated output 60 Hz | cfm |
| 494 |
|
Exhaust temp. at muffler outlet | °F |
| 1,050 |
|
|
|
|
|
|
ENGINE PARAMETERS |
|
|
|
|
Rated synchronous RPM | 60 Hz |
| 3600 |
|
HP at rated KW | 60 Hz |
| 94 |
|
|
|
|
| |
POWER ADJUSTMENT FOR AMBIENT CONDITIONS |
|
|
| |
Temperature Deration |
|
|
|
|
3% for every 10 °C above - °C |
| 25 |
| |
1.65% for every 10 °F above - °F |
| 77 |
| |
Altitude Deration |
|
|
|
|
1% for every 100 m above - m |
| 915 |
| |
3% for every 1000 ft. above - ft. |
| 3000 |
| |
|
|
|
|
|
RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with