Table 8-1Troubleshooting Guide (continued)

Symptom

Cause

Remedy

 

 

 

Hoist moving in wrong

Pendant control hoses are

Connect the control tubes in

terminated to incorrect ports on hoist

direction (pendant control)

accordance with Section 7.4.

body.

 

 

 

Hoist is overloaded.

Reduce load to hoist rated capacity.

Hoist lowers but will not lift

Faulty pendant control or control

Repair or replace pendant control or

hose(s)

control hose(s)

 

Lack of air pressure or partial loss of

Repair or adjust air supply or filters.

 

or leakage in air supply.

 

 

 

 

Inject approx. 20 drops of oil into inlet

Hoist continues running after

Main Spool sticking

port to lubricate the main spool. If

spool still sticks, repair at service

pendant or cord is released

 

 

facility.

 

 

 

Valve in Pendant Handle stuck

Repair at service facility

Hoist drifts excessively when

Brake is not holding.

Repair brake at service facility.

hoist is stopped

 

 