11

Installation of Ducting

Installation through an outside wall

range hood outlet (see Figure 4, Page 10), making sure no wall studs are cut. Push range into position. From outside of

the house, measure distance from the siding to the range outlet. Cut duct pipe that length, plus 1” (25mm) for overlap into

outlet. Mechanically attach vent hood to pipe. Caulk the back of vent hood and around pipe where it goes through wall

and into range hood outlet so caulking seals against outside siding.

Complete installation by following directions under Ventless Installation.

Installation through an attic to an outside wall

If the vent elbows are embedded in the wall, the range may be positioned as shown in Figure 5, Page 11. Continue the

through the roof with a roof cap. Seal with caulking around and under cap or hood.

Complete your installation by following directions under Ventless Installation.

14”
36cm
28”
72cm
29-1/2”
75cm
RangeHoodOutlet
3-1/4”x 10”
8cm x 25 cm
66-1/4”
169cm
56”
142cm
36-1/8”
92cm
GasInlet-1/2”NPT
Power
Cord
Exhaust
Hood
(female)
Receptacle
20”
51cm
4-3/4”
12cm
30”
76cm
39-3/4”
101cm
47-1/2”
122cm
Figure 5
Model 7200
13”
33cm.
29-1/2”
75cm
28”
72cm
56”
142cm
66-1/4”
168cm
62-3/8”
159cm
29-3/4”
76cm
36-1/8”
92cm
13-3/4”
35cm
RangeHoodOutlet
3-1/4”x 10”
8cm x 25 cm
3-3/4”
10cm
34”
86cm
GasInlet-1/2”NPT
Power
Cord Exhaust
Hood
(female)
Receptacle
Figure 6
Model 9200