Heat & Glo LifeStyle 6000GLX-IPILP-S/-R Top Vent Horizontal Termination Three Elbows, Min Max

Models: 6000GLX-IPI-S/-R 6000GLX-IPILP-S/-R

1 72
Download 72 pages 51.11 Kb
Page 25
Image 25

Top Vent - Horizontal Termination - (continued)

Three Elbows

V1 Min.

H1 Max.

 

V2 Min.

H2 Max.

 

 

 

 

 

 

 

 

 

Elbow only

2 ft.

610 mm

0 in.

 

0 mm

1 ft.

305 mm

6 in.

152 mm

3 ft

914 mm

6 in.

 

152 mm

2 ft.

610 mm

1 ft.

305 mm

6 ft.

1.8 m

1 ft.

 

305 mm

6 ft.

1.8 m

 

 

 

 

 

 

 

 

 

2 ft.

610 mm

11 ft.*

3.4 m*

2 ft.

 

610 mm

10 ft.*

3.1 m*

 

 

 

 

 

 

 

 

 

3 ft.

914 mm

16 ft *

4.9 m*

3 ft.

 

914 mm

14 ft.*

4.3 m*

 

 

 

 

 

 

 

 

*H1 + H2 = 20 ft. (6.1 m) Maximum

V1 + V2 + H1 + H2 = 40 ft. (12.2 m) Maximum

 

 

 

 

 

 

 

 

 

H2

V2

H1V1

Figure 7.5

Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R2101-900 Rev. Q • 11/08