6Vent Clearances and Framing
A. Pipe Clearances to Combustibles
WARNING
Fire Risk
Explosion Risk
Maintain vent clearance to combustibles as specifi ed.
•Do not pack air space with insulation or other materials.
•National building codes recommend using attic shield to keep loose materials/ insulation from contacting vent.
Failure to keep insulation or other materials away from vent pipe may cause fi re.
Follow vent pipe manufacturer’s instructions for all clear- ances around pipe.
B. Wall Penetration Framing
Do not pack with insulation or other materials.
Use manufacturer's installation instructions for framing dimensions
Figure 6.1 Exterior Wall Hole
For a wall penetration consult
Note: This appliance MUST terminate vertically.
C. Vertical Penetration Framing
Use
WARNING
Fire Risk
Keep loose materials or blown insulation from touching the vent pipe.
•National building codes recommend using attic shield to keep loose materials/ insulation from contacting vent.
•Hearth & Home Technologies requires the use of an attic shield.
Heatilator • GB4336/GB4992 • | 15 |