2. Adjusting a loose slide pipe
8mm Hex. Socket Set Screw
8mm Nut
Slide
Holder (A) Bushing Pipe (A)
Fig. 52
3. Inspecting the carbon brushes
After extended use of the power tool, the slide pipe
(A)and the bushing can become loose due to vibration. Never operate the tool if any components are loose to avoid personal injury.
(1) Loosen the 8mm nut and tighten the two 8mm hexagon socket set screws until the power tool operates smoothly without looseness.
(2) Properly tighten the 8mm nut after completing these adjustment.
For your continued safety and electrical shock protection, carbon brush inspection and replacement on this tool should ONLY be performed by a Hitachi Authorized Service Center.
4.About Handling the Motor (see Fig. 1)
Winding of the motor is said to be the heart of this tool. Exercise utmost caution not to damage the winding by exposing it to wash oil or water.
NOTE: Accumulation of dust and the like inside the motor can result in a malfunction. After using the motor for 50 hours or so, carry out
5.Inspecting the screws
Regularly inspect each component of the power tool for looseness.
WARNING: To prevent personal injury, never operate the power tool if any components are loose.
6.Inspecting the lower guard for proper operation
Before each use of the tool, test the lower guard (see Fig. 7) to assure that it is in good condition and that it moves smoothly.
Never use the tool unless the lower guard operates properly and it is in good mechanical condition.
7.Storage
After operation of the tool has been completed, check that the following has been performed:
(1)Trigger switch is in OFF position,
(2)Power plug has been removed from the receptacle,
31