OM-4402 Page 16

4-7. Selecting Weld Cable Sizes

Total Cable (Copper) Length In Weld Circuit Not Exceeding
Welding
Amperes
100 ft (30 m) Or Less 150 ft
(45 m) 200 ft
(60 m) 250 ft
(70 m) 300 ft
(90 m) 350 ft
(105 m) 400 ft
(120 m)
Amperes
10 – 60%
Duty Cycle 60 – 100% Duty
Cycle 10 – 100% Duty Cycle
100 4 4 4 3 2 1 1/0 1/0
150 3 3 2 1 1/0 2/0 3/0 3/0
200 3 2 1 1/0 2/0 3/0 4/0 4/0
250 2 1 1/0 2/0 3/0 4/0 2-2/0 2-2/0
300 1 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0
350 1/0 2/0 3/0 4/0 2-2/0 2-3/0 2-3/0 2-4/0
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your
distributor for the mm2 equivalent weld cable sizes. S-0007-E

4-8. Remote 14 Receptacle Information

Engine runs at weld/power speed whenever a device connected to the remote 14

receptacle is running.

NOTE
Socket* Socket Information
24 VOLTS AC
A24 volts ac.
AJ
BKI
L
24 VOLTS AC
BContact closure to A completes 24 volt ac contac-
tor control circuit. Protected by circuit breaker
CB5.
CLNH
DMG
115 VOLTS AC
I115 volts ac.
DMG
EF
115 VOLTS AC
JContact closure to I completes 115 volt ac contac-
tor control circuit. Protected by circuit breaker
CB6.

A/V

C0 to +10 volts dc output to remote control.

A/V

AMPERAGE
DRemote control circuit common.
AMPERAGE
VOLTAGE E0 to +10 volts dc input command signal from
remote control.
GND
GCircuit common for 24 and 115 volt ac circuits.
801 943-B
GND
K Chassis common.
*The remaining sockets are not used.