VISIONPRO® IAQ TOTAL HOME COMFORT SYSTEM
68-0287—04 28
7. Press Done key.

Fan Schedule

Press Fan key while in the Scheduling Screen to program the
System Fan. Choices available from the Scheduling Screen:
Auto (default position)—fan runs with equipment.
Programmable for all schedule periods (Wake, Leave, Return
and Sleep).
On—fan runs continuously (programmable for all schedule
periods).
Circ—fan runs randomly for approximately 35% of schedule
period (programmable for all schedule periods).

Fan Control

If the Fan program is scheduled, Auto is shown and any
programmable mode that is set; for example, if during Wake
period, Fan is set to Auto, only Auto is shown in the Fan area.
However, if during the Wake period, fan is scheduled to On,
both Auto and On are shown. Auto indicates fan is running its
schedule; On indicates Fan schedule is set to On.

Manual Override of Fan Schedule

Auto—fan is automatically following the Fan schedule (choices
are Auto, On or Circulate).
On—overrides Fan schedule. Fan is continuously On.
Circ—overrides Fan schedule. Fan circulates randomly for
approximately 35% of time until the Auto position is selected.
aAuto Override resumes the Fan Program in each schedule
period (Wake, Leave, Return and Sleep)
OPERATE VISIONPRO® IAQ

Set Time

1. Press Clock.
2. Use arrows to set current time.
DONE WAKE LEAVE RETURN SLEEP CANCEL
MON TUE WED THU FRI SAT SUN
FAN
HEAT
COOL
OK TO PICK MULTIPLE DAYS
M19957
SCHED
SCHED
HOLD
HOLD
CLOCK SCREEN
DONE WAKE LEAVE RETURN SLEEP CANCEL
MON TUE WED THU FRI SAT SUN
AM
PM
PM
FAN
AUTO
SYSTEM
EM HEAT
HEAT
OFF
COOL
AUTO
CANCEL
PERIOD
HEAT
COOL
Following
Schedule
Inside Set To
OK TO PICK MULTIPLE DAYS SCREEN LOCKED
M22447
SCHED HOLD CLOCK SCREEN
THU
AM
FAN
ON
AUTO
SYSTEM
HEAT
Following
Schedule
Inside Set
M23505
Humidity
Table 10. Fan Program Operation and Screen Status.
Fan
Setting
Fan
Program
Schedule
Call
for
Action
Energize
Termin al
Fan
Status
shown on
Screen
Auto Auto None None Auto
Auto On Fan G Auto/On
Auto Circ None None Auto/Circ
Auto Circ Fan G Auto/Circ
Table 11. Manual Override of Fan Schedule Operation.
Fan
Setting
Fan
Schedule
Override
Setting
Call
for
Action
Energize
Termin al
Screen
Message
Under
Fan
Setting
Auto On Fan G On
Auto Circ None None Circ
Auto Circ Fan G Circ
On Autoa —— —
On Circ None None Circ
On Circ Fan G Circ
Circ Autoa —— —
Circ On Fan G On