TrueFRESH™ ERV/HRV Ventilation Systems 69-2480EF—05 13
Ensure that you have all of the following installation items:
Installation Steps
2Installation Area
1Installation Kit
TheERV/HRVunitshouldbeinstalledinamechanicalroomor asclosetoanoutsidewallaspossible.
TheERV/HRVunitmustalwaysbeinstalledinanareawherethe airisconditionedtoavoidfreezingthe
condensate line.
The contractor should install the unit in an area that allows the homeowner easy access for maintenance.
Itisveryimportanttoinstallanelectricreceptacle(120 Vac)neartheunit,aseparatecircuitbreaker
isalsorecommended.Itisbesttohaveaccessto acondensatedrainneartheERV/HRVunittoavoid
having to use a condensate pump.
NOTE: Installation is not recommended in unconditioned areas such as an attic or crawl space where
thetemperaturecanfallbelow32ºF(0ºC).
NOTE: Ductinginunconditionedareasmustbefullysealedandinsulated.
Installation Kit:
•2Flexible6in.VinylDucts
•1CondensationDrainLine(10in.)
•1DrainAdapterwithNut
•4TieWraps(30in.)
•16Hex-headscrews(1/4x5/8in.)
•4Hex-headscrews(1/4x1in.)
•4Washers
•1Draincap(VNT5250E100andVNT5200E1000only)
•1powercord,120Vac(notshown)
4 Duct Collars