SCANNER OPERATION
INDICATOR DESCRIPTIONS
Diagnostic Indicator Display
There is a green colored (when illuminated) single digit error code display located to the left of the scanner’s mirrored polygon (see figure to the right).
Figure 34. Failure LED
ERROR |
| DESCRIPTION |
|
CODE |
|
| |
|
|
|
0RAM ERROR – The scanner’s Random Access Memory (RAM) is tested as faulty. Return the unit for repair at an authorized service center.
1PROGRAM ERROR – The scanner’s software program is failing. Return the unit for repair.
INTERFACE ERROR – After power up and any application exit (e.g.
2MetroSet, etc.), the scanner checks the interface hardware with that chosen in configuration. If they do not agree, an interface error exists.
CONFIGURATION ERROR – The
3not agree with the data last saved. Default configuration data is then used and the scanner continues operating.
COMMUNICATION ERROR – The RS232 data line is being held active.
4The scanner will abort attempts to enter configuration mode after a short timeout.
COPROCESSOR COMMUNICATION ERROR – The main
5microprocessor is not communicating with the interface coprocessor. Return the unit for repair at an authorized service center.
6LASER ERROR – The laser in the scanning system denotes a failure. Return the unit for repair at an authorized service center.
7MOTOR ERROR – The motor in the scanning system denotes a failure. Return the unit for repair at an authorized service center.
8SCALE ERROR – The scanner is not communicating with the scale.
9EAS ERROR – The scanner is not communicating with the EAS device.
36