| You must be fully aware of all the distinctive |
COMPOSITION: | features and precautions related to this |
camera before installing it. |
| |
Operation Manual | Mounting Screw |
|
DIMENSIONS(mm):
100.0
47.15 |
|
75.7 | 101.0 |
37.0 |
|
142.4
HD51 Series
INSTALLATION:
1 | Stick the guide pattern on the |
| wall or ceiling. |
SPECIFICATIONS:
Model | NTSC |
| PAL |
Signal System | NTSC : 525 Lines |
| PAL : 625 Lines |
Scanning System |
| 2 : 1 Interlace | |
Scanning Frequency (H) | 15.734kHz |
| 15.625kHz |
Operation
Manual
2 | Drill four holes according to |
| the guide pattern then insert |
| anchors into the drilled holes. |
3 | Draw out power / video wires |
| to the connecting places. |
4 | Fix the camera to a celling using |
| four screws. |
5 | Adjust desired focus and scene |
| by turning and moving the |
| |
6 | Put the dome cover over the |
| base. |
7 | Fix the dome cover on the base |
| by |
Scanning Frequency (V) | 59.94Hz |
| 50Hz |
Image Sensor | 1/3" SONY Super HAD CCD | ||
Total / Effective Pixels No. | 410K / 380K |
| 470K / 440K |
S / N Ratio | More than 50dB (AGC Off) | ||
Resolution | 550 TV Lines | ||
Video Output Level | 1.0 | ||
Lens | Fixed Lens : f=4.0mm | ||
Focus |
| Manual | |
Sync. System |
| Internal | |
Sensitivity |
| 0.3 Lux | |
Electronic Shutter | 1/60 ~ 100,000 Sec. |
| 1 /50 ~ 100,000 Sec. |
White Balance |
| Auto | |
AGC |
| On / Off | |
BLC | On / Off (with Slide Switch) | ||
Flickerless | On / Off (with Slide Switch) | ||
Input / Output Connector | Power, Video | ||
Power Consumption | 12VDC (10V~15V) / 3W (Max) | ||
Dome Size (Ø) |
| 100mm | |
Weight | Approx. 844g |
•1/3" Sony Super HAD CCD
•High Resolution:550 TV Lines
•4 - 9mm DC Vari-focal Auto Iris
•Auto White Balance
•AGC, BLC, Flickerless On/Off
•Extra Video Output for Installer
•3-Axis Camera Construction
•Vandal-Resistant Dome Housing
•Diameter of Bubble:100mm
|
| le to i | ns |
|
|
| p |
| |
|
| m | t | |
| i |
| a | |
| S |
|
| l |
• |
|
|
| l |
|
|
|
|
PRECAUTIONS:
! | Do not install the camera in |
| extreme temperature conditions. |
| Do use the camera under conditions |
| where temperatures are within |
| |
| Be especially careful with ventilation |
| under high temperatures. |
| Design and specifications are |
|
|
NAME AND FUNCTION: | subject to change without notice. | 90º | |
|
| bracket makes it much |
|
| easier to rotate in any | 360º | |
| direction. |
|
4 |
|
5 | 1 |
|
CAMERA SET-UP:
360º
! | Do not disassemble the camera. |
| There are no |
| inside it. |
! | Do not drop the camera or |
| subject them to physical shocks. |
| It can cause malfunctions to occur. |
! | Note |
3 |
2 |
| T | IO |
|
| LEVELDC | VIDEO | |
05 |
|
|
|
|
| ||
|
| J5 |
|
|
|
| |
A | ER |
| AC 24V |
|
|
| |
|
|
|
|
| |||
HE | /AUD | J503 |
| ON | 12 3 SWITCH | ||
|
|
|
|
| |||
|
|
|
|
| BLC ON | ||
|
|
|
|
| AGC OFF |
|
|
|
|
|
|
| FL ON |
|
|
b
J502 | J504 |
|
J501 | AC24V |
c
bFunction Selection Switch: •FL(Flickerless) ON/OFF •AGC(Auto Gain Control) ON/OFF •BLC(Back Light Compensation)
ON/OFFcService Monitor Connecter: Use service monitor connector to set camera angle & focus when installing.
When this camera is installed near |
wireless communication devices |
that emits strong electromagnetic |
field, irregularity such as noise on |
the monitor may appear. |
CONNECTION:
#1
Connecting toMonitor and Power12VDC Power Type | #2 |
|
1 | Tilt rotation: Adjusting the vertical angle. | 4 Focus handle: Focus (Far or Near) | ||||
2 | Pan rotation: Adjusting the horizontal angle. | 5 Zoom handle: Zoom (Tele or Wide) | ||||
3 | Horizontal rotation: Adjusting the horizontal |
| Camera | |||
|
|
| position of the screen. |
| ||
|
|
| • The wire is polarized. | • Use 12VDC | power source. | |
| Video | Video Output |
|
|
| |
| (Yellow) |
| No. Function | Terminal Color | Remark | |
|
|
| ||||
|
| GND | #1 Video Output | Yellow |
| 1.0 |
| Power - 12VDC |
| #2 Power Input | Red | 12VDC, Max 3W/ 250mA | |
| (Red) |
|
|
|
|
|
TROUBLESHOOTING:
If you have trouble operating your camera, refer to the following.If the guidelines do not enable you to solve the problem, contact an authorized technician.
The image does not | Check the power source for the monitor and camera |
appear on the screen. | and ensure that the voltage and polarity are properly |
| connected and being supplied correctly. |
The image on the | Check if the lens is stained. If dirty, clean the lens with |
screen is dim. | a soft, clean cloth. |
| Adjust the Back Focus of the lens again. |
The camera does not work | Check if you have connected the camera to a proper |
properly, the surface of the | power source and If there is no problem with the power, |
camera case is hot, and a black | turn the unit off immediately and seek assistance from |
line appears on the screen. | our Customer Service department. |
The screen blinks a lot. | Check if the camera is pointed toward the sun or a |
Adjust the angle or location of the camera if too much light is coming into the screen.