51
Summary of Audible/Visual Notifications
Fixed-Word Display Keypads
SOUND CAUSE DISPLAY
LOUD,
INTERRUPTED*
Keypad & Ext.
FIRE ALARM FIRE is displayed; zone number of zone in
alarm is displayed. If a fire alarm is
manually activated, zone number 95 will be
displayed.
LOUD,
CONTINUOUS*
Keypad & Ext.
BURGLARY/AUDIBLE
EMERGENCY ALARM ALARM is displayed. Zone number of zone
in alarm is also displayed.
ONE SHORT
BEEP
(not repeated)
Keypad only
a. SY STEM DISARM
b. SYSTEM ARMI NG ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY
a. READY i ndicator light comes on.
b. Number of the open protection zone
displayed.
c. Zone numbers of the bypassed prote ction
zones are displayed (one beep is heard for
each zone displayed). Subsequently,
BYPASS is displayed.
ONE SHORT
BEEP
(about every 30
secs)
Keypad only
a. SY STEM IS IN TEST MODE
b. LOW BATTERY AT A
TRANSMITTER
c. SYSTEM WILL AUTOARM
WITHIN 10 MINUTES
a. Opened zone numbers will appear.
b. BAT displayed with zone number of
transmitter.
c. No special display.
TWO SHORT
BEEPS
Keypad only
ARM AWAY or MAXIMUM AWAY is displayed. Red ARMED indicator is
lit.
THREE SHORT
BEEPS
Keypad only
a. ARM STAY, NI GHT-STAY,
INSTANT
b. ZONE OPENED W ITH
SYSTEM IN CHIME MODE.
a. STAY or INSTA NT is displayed. Red
ARMED indicator is lit.
b. CHIME displayed; zone number of open
protection zone will be displayed if the []
key is pressed.
RAPID
BEEPING
Keypad only
a. TROUBLE
b. MEMORY OF ALARM
c. SYSTEM LOW BATTERY
d. EXT. SOUNDER WIRING
FAIL
e. LAST 10 SEC of EXIT DELAY
a. CHECK displayed. Zone number of
troubled protection zone is displayed.
b. FIRE or ALARM i s displayed; zone
number of zone in alarm is displayed
c. BAT displayed with no zone ID number.
d. CHECK 70 is displayed.
e. No special display.
SLOW
BEEPING
Keypad only
a. EXI T DELAY WARNING
b. ENTRY DELAY W ARNING
a. AWAY is displayed.
b. Exceeding the entry delay time without
disarming causes alarm.
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.