Chapter 3 – Related MultiVOIP Setup Parameters

 

 

 

 

 

 

 

DID Interface Parameter Definitions

 

 

 

 

 

 

 

Field Name

Values

Description

 

 

 

 

 

 

 

Interface

DID-DPO

Enables the customer-premises side of DID functionality

 

 

 

 

 

 

 

DID Options

MultiVOIP’s use of DID applies only for incoming DID calls. The

 

 

 

 

Start Mode used by the MultiVOIP must match that used by the

 

 

 

 

originating telephony equipment, else DID calls cannot be

 

 

 

 

completed.

 

 

 

 

 

 

 

Start Modes

Immediate Start,

For Immediate Start, the voip detects the off-hook condition initiated

 

 

 

Wink Start,

by the telco central-office call and becomes ready to receive dial

 

 

 

Delay Dial

digits immediately.

 

 

 

 

For Wink Start, the voip detects the off-hook condition. Then the

 

 

 

 

voip reverses battery polarity for a specified time (140-290 ms; a

 

 

 

 

“wink”) and then becomes ready to receive dial digits.

 

 

 

 

For Delay Dial, the voip detects detects the off-hook condition. Then

 

 

 

 

the voip reverses battery polarity for a specified time (reverse

 

 

 

 

polarity duration has wider acceptable range than for Wink Start)

 

 

 

 

and then becomes ready to receive dial digits.

 

 

 

 

 

 

 

Wink Timer

integer values,

This is the length of the wink for Wink Start and Delay Dial signaling

 

 

(in ms)

in milliseconds

modes..

 

 

 

 

Applicable only when Start Mode parameter is set to “Wink Start” or

 

 

 

 

“Delay Dial.”

 

 

 

 

 

 

 

Dialing Options

 

 

 

Inter Digit

integer values,

This is the length of time that the MultiVOIP will wait between

 

 

Timer

in seconds

digits. When the time expires, the MultiVOIP will look in the

 

 

 

 

phonebook for the number entered.

 

 

 

 

Default = 2.

 

 

 

 

 

 

 

Message

--

Not applicable to DID-DPO interface.

 

 

Waiting

 

 

 

 

Indication

 

 

 

 

 

 

 

 

 

Inter-Digit

integer values,

This parameter is applicable when digits are dialed onto a DID-DPO

 

 

Regeneration

in milliseconds

channel after the connection has been made. The length of time

 

 

Timer

 

between the outputting of DTMF digits.

 

 

 

 

Default = 100 ms.

 

 

 

 

 

 

50