Service Tests (Diagnostics)

2The Front Panel will show the 8. Service Station submenu.

3In the 8. Service Station submenu, scroll to Primer Motor and press OK to start the test.

4The Primer Motor test starts and the front Panel displays the following messages:

„Starting Horsburgh and Mips.

„Starting Nvm.

„Getting Part Number.

„Starting Service Station.

„Starting Scan Axis.

„Moving SVS out of Sax.

„Homing Scan Axis.

„Moving Carriage out of SVS.

„Homing Service Station.

„Starting ServicingServices.

„Capping Service Station.

„Uncapping Service Station.

„Starting Primer Motor

„Starting AcumenSupplies

„Starting FluidManager

„Starting Primer

„Preparing SVS

„Reading Homing Sensor

„Zero Sensor initial value: 0.

„Step 1: current zeroSensor value: 0.

„OK: It has been detected a change in zero sensor.

„Homing Primer Motor

„Moving Primer Motor and getting traces

„Moving Primer Motor to home position

„Capping service station

5The Front Panel shows the test complete display for a few seconds.

HP Designjet T Series — Service Manual