System Support
4.4 Real-Time Clock and Configuration Memory
The
0Dh | Register D |
| 82801 | FFh |
|
| |||
0Ch | Register C |
|
| |
|
|
| ||
0Bh | Register B |
| Extended Config. |
|
0Ah | Register A |
| Memory Area |
|
09h | Year |
| (128 bytes) |
|
08h | Month |
|
| 80h |
07h | Date of Month |
|
| |
|
| 7Fh | ||
06h | Day of Week |
|
| |
| Standard Config. |
| ||
05h | Hours (Alarm) |
|
| |
04h | Hours (Timer) |
| Memory Area |
|
03h | Minutes (Alarm) |
| (114 bytes) | 0Eh |
|
| |||
02h | Minutes (Timer) |
|
| |
| RTC Area | 0Dh | ||
01h | Seconds (Alarm) |
| ||
| (14 bytes) | 00h | ||
00h | Seconds (Timer) |
|
|
CMOS
Figure
A lithium
4.4.1 Clearing CMOS
The contents of configuration memory can be cleared by the following procedure:
1.Turn off the unit.
2.Disconnect the AC power cord from the outlet and/or system unit.
3.Remove the chassis hood (cover) and insure that no LEDs on the system board are illuminated.
4.On the system board, press and hold the CMOS clear button (switch SW50, colored yellow) for at least 5 seconds.
5.Replace the chassis hood (cover).
6.Reconnect the AC power cord to the outlet and/or system unit.
7.Turn the unit on.
✎The above procedure does not clear the Power On Password. To clear the
www.hp.com | Technical Reference Guide |