AC Controls
Manual Starters and Switches
General
Table 15.1 Horsepower Ratings
| Maximum Horsepower | ||
| AC Single Phase | DC | |
Voltage |
| ||
1 | 1 | 3⁄4 | |
277 | 1 | 1 | — |
Table 15.2 | Horsepower Ratings |
|
|
|
|
|
| ||
| Number |
| AC Ratings |
| DC Ratings |
| |||
| of | Motor Type | 115 | 230 | 90 | 115 | 230 | ||
Device | Poles | AC | Volts | Volts | Volts | Volts | Volts | Volts | |
Class | 2 | Single Phase | 2 | 2 | 3 | 1 | 2 | 11⁄2 | |
MMS | 3 | Three Phase | 2 | 71⁄2 | 10 | 1 | 2 | 11⁄2 | |
Class | 2 | Single Phase | 2 | 2 | 3 | 1 | 2 | 11⁄2 | |
MRS | 3 | Three Phase | 2 | 71⁄2 | 10 | 1 | 2 | 11⁄2 | |
Class | 2 | Single Phase | 2 | 2 | 3 | 1 | 2 | 11⁄2 | |
| 3 Phase, Constant |
| 71⁄2 |
|
|
| 11⁄2 | ||
MMS | 3 | 2 | 10 | 1 | 2 | ||||
or Var. Torque | |||||||||
Two |
|
|
|
|
|
|
| ||
Speed | 3 | 3 Phase, | 2 | 71⁄2 | 10 | 1 | 2 | 1 | |
|
| Constant HP |
|
|
|
|
|
|
15
AC Controls
Table 15.3 | Manual Starters and Switches Features |
|
|
|
|
| |
Class SMF Fractional Horsepower | Class MRS and MMS Manual |
| |||||
Manual Starters with Melting | Switches |
|
|
|
| ||
Alloy Type Thermal Overload Relay, |
|
|
|
|
| ||
Single Unit Types |
|
|
|
|
|
| |
Type of | No. of |
| Type of | No. of |
|
|
|
Operator | Poles | Features | Operator | Poles |
| Features |
|
Basic Starter |
|
| Class MMS — |
| |||
Toggle | 1 |
| Toggle | 1 |
| Standard With Pilot Light (115 and 230 VAC) | |
| 2 | Standard With Red Pilot Light |
| 2 |
| Standard With Pilot Light | |
Key | 1 | Key | 1 |
| Standard With Pilot Light (115 and 230 VAC) | ||
|
| ||||||
| 2 |
|
| 2 |
| Standard With Pilot Light | |
Starter With Handle Guard / |
|
|
|
| Features | ||
Toggle | 1 |
| Type of | No. of |
| Suitable for | (Incl. Mechanical |
| Operator | Poles |
| Motor Types | Interlock) | ||
| 2 | Standard With Red Pilot Light | Class MMS — Reversing |
|
| ||
| 1 |
|
| ||||
|
| Toggle | 2 |
| Std. With Pilot Light | ||
| 2 |
|
| Winding | (115 and 230 VAC) | ||
|
|
|
|
| |||
One Starter In Duplex Enclosure |
|
|
| Std. With Pilot Light | |||
Toggle | 2 |
|
| 3 |
| Capacitor, | |
|
| Standard With Red Pilot Light |
|
|
| ||
Key | 2 |
|
|
| |||
|
|
| Class MMS — |
| |||
Two Starters In One Enclosure |
| ||||||
Toggle | 2 Each |
| Toggle | 2 |
| Std. With 2 Pilot Lights | |
| Standard With Red Pilot Light On Each |
|
|
| Winding | (115 and 230 VAC) | |
|
|
|
| ||||
Key | Str. |
|
|
|
| Std. With 2 Pilot Lights | |
Starter and |
| 3 |
| Separate Winding | |||
Toggle | 1 | Standard With Red Pilot Light |
|
|
| ||
|
|
|
|
| |||
| 2 |
|
|
|
|
| |
|
|
|
|
|
|
| |
Key | 2 | With Red Pilot Light |
|
|
|
|
|
|
|
|
|
| |||
Toggle | 1 | With Mechanical Interlock (Standard With 2 Red Pilot Lights) |
|
|
|
|
|
| 2 | With |
|
|
|
|
|
Table 15.4 Class SMF Heater Elements
Motor | Heater | Motor | Heater | Motor | Heater | Motor | Heater | ||
Current (Amperes) | Cat. No. | Current (Amperes) | Cat. No. | Current (Amperes) | Cat. No. | Current (Amperes) | Cat. No. | ||
SMF H01 | SMF H014 | 1.80 | SMF H027 | 5.86 | SMF H40 | ||||
SMF H02 | SMF H015 | SMF H028 | SMF H41 | ||||||
SMF H03 | SMF H016 | SMF H029 | SMF H42 | ||||||
SMF H04 | SMF H017 | SMF H030 | 7.58 | SMF H43 | |||||
SMF H05 | SMF H018 | SMF H031 | 8.16 | SMF H44 | |||||
SMF H06 | SMF H019 | SMF H032 | 8.99 | SMF H45 | |||||
SMF H07 | SMF H020 | SMF H033 | 9.68 | SMF H46 | |||||
SMF H08 | SMF H021 | SMF H034 | 9.96 | SMF H47 | |||||
SMF H09 | SMF H022 | SMF H035 | 10.9 | SMF H48 | |||||
SMF H010 | SMF H023 | SMF H036 | SMF H49 | ||||||
SMF H011 | SMF H024 | SMF H037 | SMF H50 | ||||||
SMF H012 | SMF H025 | SMF H038 | 14.0 | SMF H51 | |||||
SMF H013 | SMF H026 | SMF H039 | SMF H52 |
286 | Siemens Electrical Products and Systems | CSI Section 16160 | |
Specification Guide | |||
|
|