/dev/rdsk/c6t12d0 /dev/rdsk/c9t12d0 |
|
| ||||
HORCM_DEV |
|
|
|
|
|
|
#dev_group | dev_name port# |
| TargetID LU# MU# |
| ||
dg12 | dg12_d0 | 6 | 5 |
| ||
#Phantom device group dg13 |
|
|
|
|
| |
dg13 | dg13_d0 | 6 | 5 | h2 | ||
HORCM _INST |
|
|
|
|
|
|
#dev_group | ip_address |
| service |
|
| |
dg12 | NodeB.dc2.net | horcm0 | # communicate with DC2 nodes | |||
dg13 | NodeC.dc3.net | horcm0 | # communicate with DC3 nodes |
Sample Raid Manager Configuration on a DC2 NodeB
HORCM | _MON |
|
|
#ip_address service | poll(10ms) | timeout(10ms) | |
NodeB | horcm0 | 1000 | 3000 |
HORCM_CMD
#dev_name dev_name dev_name /dev/rdsk/c21t8d0 /dev/rdsk/c24t8d0
HORCM_DEV
#dev_group dev_name port#
dg12dg12_d0
dg23dg23_d0
TargetID LU# | MU# |
| |
13 | 1 |
| |
13 | 1 | h1 |
HORCM _INST |
|
|
|
|
|
|
|
#dev_group | ip_address | service |
|
|
|
|
|
dg12 | NodeA.dc1.net | horcm0 | # | communicate | with | DC1 | nodes |
dg23 | NodeC.dc3.net | horcm0 | # | communicate | with | DC3 | nodes |
Sample Raid Manager Configuration on a DC3 NodeC
HORCM _MON |
|
|
|
|
|
|
|
#ip_address service | poll(10ms) | timeout(10ms) |
| ||||
NodeC | horcm0 | 1000 |
|
|
| 3000 |
|
HORCM_CMD |
|
|
|
|
|
|
|
#dev_name dev_name dev_name |
|
|
|
|
| ||
/dev/rdsk/c6t2d0 /dev/rdsk/c8t2d0 |
|
|
| ||||
HORCM_DEV |
|
|
|
|
|
|
|
#dev_group | dev_name | port# |
| TargetID LU# MU# |
| ||
dg23 | dg23_d0 | 0 | 5 | h1 | |||
#Phantom device group dg13 |
|
|
|
|
| ||
dg13 | dg13_d0 | 0 | 5 | h2 | |||
HORCM _INST |
|
|
|
|
|
|
|
#dev_group | ip_address |
|
| service |
|
| |
dg23 | NodeB.dc2.net | horcm0 | # communicate with DC2 nodes | ||||
dg13 | NodeA.dc1.net | horcm0 | # communicate with DC1 nodes |
The sample RAID Manager configuration files on DC1, DC2, and DC3 nodes for
Configuring an P9000 or XP 3DC DR Solution 435