P/N 0425683F

®

APPENDIX A –

The diagrams below may be of

wiring must be done in accor-

REPLACEMENT BALLAST

assistance when changing from

dance with NEC and local

WIRING

one ballast type to another. All

codes.

Please note that line side is on top

Red

Red

Blue

Blue

Black

White

Single lamp wiring same as old.

Two lamp wiring has a red wire from each lamp spliced together. Two blues and one red go to the ballast as a group.

Blue Blue

Red

Red

Red

Red

Blue Blue

Black

White

HUSSMANN / SYL - QT 2X54/120PHC

P/N 0425671

 

L

Blue Blue

 

 

N

Red

Red

 

Red

Red

 

 

 

Blue Blue

 

 

HUSSMANN / Jamicon 2/F58/120V

P/N 0430330

Note that one lamp goes to top 3 pins other lamp to bottom 3 pins with a common connection between them.

N

Blue Blue

L

G

Blue

Red

Red

Red

Blue

Please note: Neutral on top Power / Line middle Ground bottom

Two lamp wiring has a red wire from each lamp spliced together and returning to the ballast.

Two blues and one red go to the ballast as a group from each lamp.

24