IBM A40I TYPE 2271, A40P TYPE 6841 Use caution do not become a victim yourself Switch off power

Models: A40 TYPE 6840 A40P TYPE 6841 A40I TYPE 2271

1 148
Download 148 pages 31.48 Kb
Page 132
Image 132

Observe the following rules when working on electrical equipment.

vFind the room emergency power-off (EPO) switch, disconnecting switch, or electrical outlet. If an electrical accident occurs, you can then operate the switch or unplug the power cord quickly.

vDo not work alone under hazardous conditions or near equipment that has hazardous voltages.

vDisconnect all power before:

Performing a mechanical inspection

Working near power supplies

Removing or installing main units

vBefore you start to work on the machine, unplug the power cord. If you cannot unplug it, ask the customer to power-off the wall box that supplies power to the machine and to lock the wall box in the off position.

vIf you need to work on a machine that has exposed electrical circuits, observe the following precautions:

Ensure that another person, familiar with the power-off controls, is near you.

Remember:Another person must be there to switch off the power, if necessary.

Use only one hand when working with powered-on electrical equipment; keep the other hand in your pocket or behind your back.

Remember:There must be a complete circuit to cause electrical shock. By observing the above rule, you may prevent a current from passing through your body.

When using testers, set the controls correctly and use the approved probe leads and accessories for that tester.

Stand on suitable rubber mats (obtained locally, if necessary) to insulate you from grounds such as metal floor strips and machine frames.

Observe the special safety precautions when you work with very high voltages; these instructions are in the safety sections of maintenance information. Use extreme care when measuring high voltages.

vRegularly inspect and maintain your electrical hand tools for safe operational condition.

vDo not use worn or broken tools and testers.

vNever assume that power has been disconnected from a circuit. First, check that it has been powered-off.

vAlways look carefully for possible hazards in your work area. Examples of these hazards are moist floors, nongrounded power extension cables, power surges, and missing safety grounds.

vDo not touch live electrical circuits with the reflective surface of a plastic dental mirror. The surface is conductive; such touching can cause personal injury and machine damage.

vDo not service the following parts (or similar units) with the power on when they are removed from their normal operating places in a machine. This practice ensures correct grounding of the units.)

Power supply units

Pumps

Blowers and fans

Motor generators

vIf an electrical accident occurs:

Use caution; do not become a victim yourself.

Switch off power.

Send another person to get medical aid.