IBM A40I TYPE 2271, A40P TYPE 6841, A40 TYPE 6840 manual

Models: A40 TYPE 6840 A40P TYPE 6841 A40I TYPE 2271

1 148
Download 148 pages 31.48 Kb
Page 60
Image 60

Diagnostic Error Code

FRU/Action

 

 

 

170-195-XXX

1.

Information

Voltage Sensor(s) Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

170-196-XXX

1.

Press F3 to review the log file

Voltage Sensor(s) test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

170-197-XXX

1.

Make sure the component that is called

Voltage Sensor(s) test warning

 

out is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

170-198-XXX

1.

If a component is called out, make sure

Voltage Sensor(s) test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problems

 

 

section

 

 

 

170-199-XXX

1.

Go to the Undetermined problems

Voltage Sensor(s) test failed, cause unknown

 

section

 

 

 

2.

Flash the system and re-test

 

3.

Replace component under function test

 

 

 

170-250-XXX

1.

Power supply

170-251-XXX

2.

System board

Voltage Sensor(s) Voltage limit error

 

 

 

 

 

170-254-XXX

1.

Voltage Regulator Module (VRM)

Voltage Sensor(s) Voltage Regulator Module

2.

Microprocessor

error

3.

System board

 

 

 

 

175-000-XXX

1.

No action

Thermal Sensor(s) Test Passed

 

 

 

 

 

175-0XX-XXX

1.

Flash system

Thermal Sensor(s) failure

2.

System board

 

 

 

 

175-195-XXX

1.

Information

Thermal Sensor(s) Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

175-196-XXX

1.

Press F3 to review the log file

Thermal Sensor(s) test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

175-197-XXX

1.

Make sure the component that is called

Thermal Sensor(s) test warning

 

out is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

175-198-XXX

1.

If a component is called out, make sure

Thermal Sensor(s) test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test

 

3.

Go to Undetermined problemssection

 

 

 

54Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer

Page 60
Image 60