USER RESPONSIBLE FOR VERIFYING VERSION AND COMPLETENESS
OEM FUNCTIONAL SPECIFICATION ULTRASTAR XP (DFHC) SSA MODELS 1.12/2.25 GB -1.0" HIGH
1.0 Description

1.1 Features

1.1.1 General Features

1.12/2.25/4.51 gigabytes formatted capacity (512 bytes/sector)
Serial Storage Architecture (SSA) attachment (dual port)
Brick On Sled carrier and 3.5" small form factor models
Rotary voice coil motor actuator
Closed-loop digital actuator servo (embedded sector servo)
Magnetoresistive (MR) heads
(0,8,6,infinity) 8/9 rate encoding
Partial Response Maximum Likelihood (PRML) data channel with digital filter
All mounting orientations supported
Jumperable auto spindle motor start
Jumperable write protection
Spindle synchronization
Two LE D drivers
Bezel (optional)

1.1.2 Performance Summary

Average read seek time (1.12 GB): 6.9 milliseconds
Average read seek time (2.25 GB): 7.5 milliseconds
Average read seek time (4.51GB): 8.0 milliseconds
Average Latency: 4.17 milliseconds
Split read/write control
Media data transfer rate: 9.59 to 12.58 MegaBytes/second (10 bands)
SSA data transfer rate: 20 Megabytes/second

1.1.3 Interface Controller Features

Multiple initiator support
Supports blocksizes from 256 to 5952 bytes
512K byte, multi-segmented, dual port data buffer
Read-ahead caching
Adaptive caching algorithms
Write Cache supported (write back & write thru)
Tagged command queuing
Command reordering
Back-to-back writes (merged writes)
Split reads and writes
Nearly contiguous read/write
Link error recovery procedure exit
Disable registration
Duplicate tags
Two byte U LP message codes
SCSI response
Move data transfer messages
Multiple ULP's
Automatic retry and data correction on read errors
Source filename=DESCRIP IBM Corporation Page 9 of 87