48
11 DIGITALMODE OPERATION
EMR communication
The EMR communication mode is available for digital mode
operation. In the EMR communication mode, no call sign set-
ting is necessary. When an EMR communication mode sig-
nal is received, the audio (voice) will be sound in the specied
level (‘12’ level) even the volume setting is set to any level.
qSet the desired frequency then push [A•
FUNC
]and [0•
OPT
]
to enter
OPTION SET MODE
.
wPush [YY]or [ZZ]several times to select the EMR setting,
then rotate [VOL] to turn the EMR setting ON.
“EmR” appears.
ePush [
ENT
](or [D•
CLR
]) to exit
OPTION SET MODE
, then
operate the transceiver normal way.
rTo cancel the EMR communication mode, push [A•
FUNC
]
and [0•
OPT
], then rotate [VOL] to turn OFF.
Pocket beep operation
This function uses a digital code/call sign for calling and can
be used as a “common pager” to inform you that someone
has called while you were away from the transceiver. The dig-
ital code or call sign squelch does not function while in a low-
speed data communication.
DDWaiting for a call from a specic station
qSet the operating frequency.
wProgram the digital code or call sign.
See p. 53, “Digital code setting” or p. 42 “Call sign program-
ming.”
ePush [A•
FUNC
]and [1•
TONE
]one or more times until “
or “ ” appears in the function display.
•“ ” for call sign squelch; “ ” for digital code squelch operation.
rPush [A•
FUNC
], then push [2•
P
.
BEEP
]to activate the pocket
beep function.
•“” appears.
tWhen a signal with the matched call sign/digital code is re-
ceived, the transceiver emits beep tones and blinks “ .”
Beep tones sound for 30 sec. and “ ” blinks. To stop the beeps man-
ually, push any key. “ ” continues blinking until step yis operated.
yPush [PTT] to answer.
• “ ” disappears and cancels the pocket beep function automati-
cally.
uTo cancel the call sign/digital code squelch, push [A•
FUNC
]
and [1•
TONE
]one or more times until or “ ” or “ ” disap-
pears.