Port VLAN
The Port VLAN mode allows you to configure the iMcV-Giga-FiberLinX-II to accept
only data tagged with one specific VLAN ID. This mode can be configured for either
the OPTICS (or UPLINK) port or the DATA port.
VLAN on DATA Port–Configuration
To configure this mode, perform the following:
1.
In the Main Configuration screen, press the
space bar
and type
config
. The
Configuration screen displays:
2.
Enter
N
in the Transparent Mode field and press any key (except S or Q) to open
the VLAN screen:
3.
Enter
Y
in the Tags column of the Data row and
N
in the Optics row. Enter a
VLAN ID in the VLAN IDs Current column of the OPTICS row (for example, 13).
VLAN IDs Priorities Tags
Current Saved Current Saved
Ports Data VLANs are used only Optics [0 ] [13 ] [0 ] [0 ] [ N ] if Tags are enabled on both
Data [0 ] [0 ] [0 ] [0 ] [ Y ] the Optics and Data Ports.
Saved VLAN Values <Active after reboot>. Current VLAN Values <Active now>.
Tags VLAN IDs Priorities
Current Saved Current Saved
Ports Data VLANs are used only Optics [0 ] [0 ] [0 ] [0 ] [ N ] if Tags are enabled on both
Optics and Data Ports. Data [0 ] [0 ] [0 ] [0 ] [ N ] the
Management VLAN EXT Mgmt Tag
NMP [0 ] [0 ] [0 ] [0 ] [ N ] S
Data VLANs <Optics <----> Data>
VLAN 1 [0 ] [0 ] VLAN 12 [0 ] [0 ] VLAN 23 [0 ] [0 ]
VLAN 2 [0 ] [0 ] VLAN 13 [0 ] [0 ] VLAN 24 [0 ] [0 ]
VLAN 3 [0 ] [0 ] VLAN 14 [0 ] [0 ] VLAN 25 [0 ] [0 ]
VLAN 4 [0 ] [0 ] VLAN 15 [0 ] [0 ] VLAN 26 [0 ] [0 ]
VLAN 5 [0 ] [0 ] VLAN 16 [0 ] [0 ] VLAN 27 [0 ] [0 ]
VLAN 6 [0 ] [0 ] VLAN 17 [0 ] [0 ] VLAN 28 [0 ] [0 ]
VLAN 7 [0 ] [0 ] VLAN 18 [0 ] [0 ] VLAN 29 [0 ] [0 ]
VLAN 8 [0 ] [0 ] VLAN 19 [0 ] [0 ] VLAN 30 [0 ] [0 ]
VLAN 9 [0 ] [0 ] VLAN 20 [0 ] [0 ] VLAN 31 [0 ] [0 ]
VLAN 32 [0 ] [0 ] VLAN 10 [0 ] [0 ] VLAN 21 [0 ] [0 ]
VLAN 11 [0 ] [0 ] VLAN 22 [0 ] [0 ]
d 7. Valid VLAN IDs are between 1 and 4094. Vali priorities are between 0 and
T
yp
e S or F3 to save the chan
g
es. T
yp
e Q o
r
F4 to
q
uit and cancel chan
g
es.
Transparent Mode
–
w
ith either (not both) Data and Optics Mgmt dipswitches
set to on, all traffic passes between Optics and Data port EXCEPT what has
been defined as the Management Domain. The Management Domain can either be
efined as untagged traffic or traffic with a specified VLAN ID. d
In Transparent Mode with BOTH Optics and Data Mgmt dipswitches set to off,
ll traffic passes between the Optics and Data Ports. a
efault Mode – the unit passes only Untagged Packets. D
he unit is currently in Default Mode. T
Enter Y for Transparent Mode, N for no Transparent Mode or <enter> to
move to other options [ N ]