Testing with Pseudorandom Bit Sequence (PRBS)
To test the copper segment from the Remote module to the Customer Premises
Equipment (CPE) by using PRBS, perform the following:
1.
Set the CPE to loopback the signal.
2.
Set the Remote module to generate PRBSs
(DIP switch S2-9=On and S2-10=Off).
Check the LEDs to verify errors are not received (refer to the Module LED Functions
section for more information).
18