IN134UST/IN136UST User’s Manual

56
APPENDIX I

Communication

The following table describes the serial communication configuration that should be used when
interfacing to the CLI via the serial port.
Windows HyperTerminal or Procomm are two tools that can be used to send CLI commands across
the serial port.

Setting Value

Bits per second 19200
Data bits 8
Parity None
Stop bits 1
Flow control None
Emulation VT100

No Function Command RW Min Max Default Step Parameter
1 AC Power On
(Auto power on) APO RW 0 1 0 1
0: Disable; 1: Enable
3 Aspect Ratio ARZ RW 0 4 0 1
0:Fill
1:4:3
2:16:9
3:Letterbox
4:Native
4 Auto Image AIM W n/a 1 1 1 1: Enable
5 Auto Off Time AOT RW 0 36 6 1
0: Never
1: 5min
2,3…5,
6: 30min (Default 6*5=30)
7,8…35,
36: 180min
6 Auto Source ASC RW 0 1 1 1 0: Disable; 1: Enable
7 Blank Screen BLK RW 0 1 0 1 0: Disable; 1: Enable
9 Brightness BRT RW 0 100 50 1 Display Mode=User only
11 Ceiling
(Projection mode) CEL RW 0 3 0 1
0:Front
1:Rear
2:Ceiling
3:Ceiling+Rear
12 Closed Captions: Non-
Muted CLC RW 0 1 0 1
Off
On (CC1)
14 Color CLR RW 0 100 50 1 Video SVideo only = satura-
tion
15 Color Space CSM RW 0 2 0 1
Display Mode=User only
0:Auto
1:RGB
2:YUV