OPERATOR’S MANUAL 66172-X
RELEASED: 11-4-91
REVISED: 6-2-10
(REV. F)
INCLUDING: SERVICEKIT, TROUBLESHOOTING, PARTS LIST,DISASSEMBLY & REASSEMBLY

TWO-BALL STYLE

LOWER PUMP END

ALSOCOVERS 637012 -X& 637013 SERVICE KITS

READ THIS MANUAL CAREFULLYBEFORE INSTALLING,

OPERATINGO RSERVICING THIS EQUIPMENT.

Itis the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

SERVICE KITS

Use only genuine ARO replacement parts to assure compatible
pressurerating and longest service life.
637012-Xfor general repair of 66172-X lower pump end.
637013for repair of lower ball and seat.

GENERAL DESCRIPTION

WARNING DONOT EXCEED MAXIMUM OPERATINGPRES -
SUREAS INDICATED ON PUMP MODEL PLATE.
WARNING REFER TO GENERAL INFORMATION SHEET
FORADDITIONAL SAFETY PRECAUTIONS AND IMPORTANT
INFORMATION.
Thismanualonly covers the lower pump section, it is one of four doc-
umentswhich support an ARO pump. Replacement copies of these
formsare available upon request.
-650XXX-XXX-XPUMP MODEL OPERATOR’S MANUAL.
-GENERALINFORMATION FOR AIR OPERATED OR
HYDRAULICALLYOPERATED PUMPS.
=LOWERPUMP END OPERATOR’S MANUAL.
-AIROR HYDRAULIC MOTOR OPERATOR’S MANUAL
Thetwo-ball design provides better priming of the lower foot valve.
Thedouble acting feature is standard in all ARO industrial pumps,
materialis delivered to the pump discharge outlet on both the upand
downstroke.

MAINTENANCE

Theair / hydraulic motor is completely separate from the lower pump end.
Thishelps to keep the motor from being contaminated by the material being
pumped.Periodically, flush entire pump system with a solvent that is com-
patible with the material being pumped.
Keepsolvent cup filled with this compatible solvent. This will keep mate-
rialfrom drying on the piston rod, which would drag thru t he packings,
ruinthem and eventually scour the piston rod.
Providea clean work surface to protect sensitive internal moving parts
fromcontamination from dirt and foreign matter during disassembly and
reassembly.
Beforereassembling, lubricate parts as required. When assembling “O”
rings,or parts adjacent to “O” rings, exercise care to prevent damage to
“O”rings and “O” ring groove surface.

LOWER PUMP END DESCRIPTION CHART

66172 - X

PACKINGMATERIAL
0 ThiokolLeather (upper and lower)
1 GlassFilled PTFE (upper and lower)
2 GlassFilled PTFE / Leather staggered (upper and lower)
3 UHMW-PE(upper & lower)
66172- X
637012- X
Packing
SERVICEKIT SELECTION
EXAMPLE:Lower Pump End # 66172-1
ServiceKit # 637012-1

TROUBLE SHOOTING

No material at outlet (pump continually cycles). Check material
supply,disconnector shut off the air supply and replenish the material,
reconnect.
Materialonone stroke only (fast downstroke). The(21) lower ball
maynot be seating in the (22) seat (see lower pump disassembly).
Removethe ball from the seat, clean and inspect the ball and seat
area.If the ball or seat is damaged, replace.
Materialon one stroke only (fast upstroke). Check for worn or dam-
agedpackings and seals. Replace the packings and seals as neces-
sary.
Materialleakage out of the solvent cup or material appears on
thepump plunger rod. Relieve the pressure in the pump and tight-
enthe solvent cup until leakage discontinues. If this procedure does
notaid in stopping the leakage problem, the upper packings may be
worn(see lower pump disassembly). Replace the packings as nec-
essary.
INGERSOLL RAND COMPANY LTD
209 NORTH MAIN STREET – BRYAN, OHIO 43506
(800) 495-0276 FAX(800) 892-6276 © 2010
www.ingersollrandproducts.com CCN 99442972