The following abbreviations are used to represent values for Control Module Pin-Out data
I Input PG Power Ground CAN CAN Network D Serial and Encoded Data
O Output SS Sensor / Signal Supply V SCP SCP Network V Voltage (DC)
B+ Battery Voltage SG Sensor / Signal Ground D2 D2B Network PWM Pulse Width Modulated
CAUTION: The information on this data page is furnished to aid the user in understanding circuit operation. THIS INFORMATION SHOULD BE USED FOR
REFERENCE ONLY.
NOTE: The characteristics listed are approximately those that can be expected at the control module connector pins with all circuit connections made and all
components connected and fitted.
Refer to the front of this book for detailed information and illustrations regarding the location and identification of harnesses, relays, fuses, grounds, control
modules and control module pins.
DATE OF ISSUE: December 2001
Fig. 01.5
COMPONENTS
Component Connector(s) Connector Description Location
BATTERY SAVER RELAY — — CENTRAL JUNCTION FUSE BOX R21
CENTRAL JUNCTION FUSE BOX CA75 8-WAY / GREY PASSENGER COMPARTMENT, FRONT BULKHEAD LH SIDE
CA76 16-WAY / GREEN
CA77 2-WAY / GREY
CA78 16-WAY / GREY
IP1 14-WAY / GREEN
IP2 16-WAY / GREY
IP3 2-WAY / GREY
IP4 14-WAY / GREY
JB50 4-WAY / GREY
JB51 16-WAY / BLUE
JB52 2-WAY / BLACK
GENERAL ELECTRONIC CONTROL MODULE CA86 23-WAY / GREY BEHIND INSTRUMENT PANEL RH SIDE
CA87 23-WAY / GREEN
IP5 23-WAY / BROWN
IP6 23-WAY / WHITE
JB172 23-WAY / BLUE
HARNESS IN-LINE CONNECTORS
Connector Connector Description Location
CA16 20-WAY / BLACK / DOOR HARNESS TO CABIN HARNESS DRIVER SIDE A POST
CA21 20-WAY / BLACK / DOOR HARNESS TO CABIN HARNESS DRIVER SIDE A POST
CA36 16-WAY / GREEN / CABIN HARNESS TO ROOF HARNESS LH LOWER A POST
GROUNDS
Ground Location
G4 PASSENGER COMPARTMENT / RH LOWER A POST
G5 PASSENGER COMPARTMENT / RH LOWER A POST
FOR CONTROL MODULE PIN-OUT INFORMATION, UNFOLD PAGE TO LEFT.
CONTROL MODULE PIN-OUT INFORMATION
General Electronic Control Module
Pin Description and Characteristic
PG CA86-5 POWER GROUND: GROUND
O IP5-20 BATTERY SAVER RELAY DRIVE: TO ACTIVATE, GECM SWITCHES CIRCUIT TO GROUND
SG IP6-1 LOGIC GROUND: GROUND
B+ JB172-5 BATTERY POWER SUPPLY (TURN SIGNALS): B+