www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600

 

This Data Sheet Includes Information On

 

Jenn-Air

 

Product Model Number (s):

 

30" Gas Cooktops:

 

 

JGC8430BDS, JGC8430BDB, JGC8430BDQ and

 

JGC8430BDW

 

Dimensions (Actual Size)

 

Overall width:

30"

 

Overall depth:

21 3/4"

Distance from top of counter to bottom of unit: 3 13/16"

Cut-Out width: 28 3/4"

30"

3 13/16"

21 3/4"

 

Side View (not to scale)

Overall Dimensions

Top View (not to scale)

Cut-Out depth: 20 5/8"

Min. spacing from cooktop edge to nearest vertical combustible wall to the RIGHT: 8"

20 5/8"

Cut-Out Dimensions

Countertop View

(not to scale)

Min. spacing from cooktop edge to nearest vertical combustible wall to the LEFT: 8"

Min. spacing from cooktop edge to nearest vertical combustible wall to the REAR: 1 1/2"

Minimum spacing to front edge of counter: 2"

Minimum distance between cooktop

28 3/4"

and cabinet directly above: 30" min

Minimum width of cabinet directly above: 30"

Maximum depth of cabinets directly above and adjacent: 13"

Minimum distance between countertop and adjacent cabinet above: 18"

Additional Information

• Distance from top of counter to bottom of gas stub is

3 7/16".

• Distance from top of counter including manifold

entrance is 7 13/16".

• Electrical requirements : 110/120 volt AC, 60hz. Must

be grounded. 15amp circuit required. Locate outlet

below the cooktop a minimum of 5" below the

countertop if not installing over an under counter oven.

Locate outlet below the oven or in an adjacent cabinet

when installing over an adjacent under counter oven.

• Minimum clearance from top of counter to combustible

material below is 4 7/16"

• Countertop must be supported within 3" of cutout.

• Unit may be installed over a Jenn-Air under counter

30"

30" min

18"

Cabinet Requirements

Wall View (not to scale)

Minimum horizontal clearance between the edge of the appliance and combustible construction extending from the cooking surface to 18" above the cooking surface is 2" (see solid areas)

oven.

See page 2 for additional information

Subject to change without notice. This system is designed to

 

be updated daily if necessary. Dimension Express is not

 

responsible for use of superseded, voided, or outdated data

 

sheets. Because of the difficulty or impracticability of deter-

 

mining actual damages, liability of Dimension Express shall

 

not exceed $50.00.

 

Copyright © Dimension Express, 2004.

321

C

L

12 7/16"

1 13/16"

Gas inlet location
Top view of cutout
(not to scale)
Cooktop supplied with 1/2" NPT female inlet on regulator (shipped loose)

• NEVER reuse Data Sheets. Data Sheets are subject to change without

• Call Dimension Express if you have any questions at (775) 833-3633

notice. Dimension Express is a FREE service bureau and is updated daily,

• Always refer to a current Code at a Glance or manufacturer directory •

it makes far more sense to spend the time necessary to request new Data

• Data Sheet codes change on the first of odd numbered months at 12:01am •

Sheets for each project, as opposed to the problems, time, costs, and risks

BN182.34 • A321B149 • • 041201 • 7461 • 64521

associated with reusing old Data Sheets.