ID Conflict

When two devices share the same ID, a conflict occurs. This should not happen
unless two or more enclosures are daisy chained together. If devices in one
enclosure conflict with devices in another enclosure, the devices will re-arbitrate
ID and resolve the conflict.

Option Settings

Three option settings are located on the personality card. To access the jumpers,
the cover must be removed. The figure below shows the location of the option
settings on the personality card.

Delayed Start Option Jumper

Header W1 pins 1 & 2.
Jumper on = enabled.
Jumper off = disabled (default).

Remote Start Option Jumper

Header W1 pins 3 & 4.
Jumper on = enabled.
Jumper off = disabled (default).

Front Status LEDs

A status indicator is located on each canister. A 'Blue' light indicates normal
drive activity. A 'Red' light indicates a device fault. If all canisters display a 'Red'
light that is blinking on and off it indicates that there is a system fault. A system
fault is either a power supply or blower failure. Check the back of the unit to
determine which fault has occurred. Refer to Chapter 5 for blower fault indicator
location and to Chapter 6 for power supply fault indicator location.
4-3
FORTRA15-bay I6 Infortrend 5251F6 Installation Guide Rev A
W1*
Delayed Start
& Remote Start
* Located on the mid-plane board.
Status
Indicators
A blue light on a single canister
indicates device activity or busy.
A red light on a single canister
indicates a device fault.