RECORDING Backup recording function

By linking this unit to other DV devices, this unit can perform continuous, long-hour recording. This unit can be set as a backup unit connected to a DV camcorder (GY-DV300/DV500/DV550/ DV5000, etc.). When the recording tape of the source unit ends, this unit can start recording. This enables long-hour recording.

Backup unit: the main unit

 

 

OPERATE

 

 

 

 

 

EJECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MENIU

 

 

Mini

 

A.DUB

 

REC

PLAY

PAUSE

 

 

 

 

 

DVCAM NTSC PAL

REC INH.

 

 

DV cable

 

PROFESSIONAL

 

 

CH-1/3

 

 

 

 

SERIAL

LINE

REW

STOP

SET

 

CH-2/4

FF

 

 

MIC REMOTE SEL.

INPUT SEL.

 

DV terminal

DV terminal

9PIN

WIRELESS

DV Y/C

BR-DV3000

 

 

 

INPUT SEL. switch

Connection

Connect the DV terminal of the source unit to the DV terminal of this unit with a DV cable.

Setting up this unit

Set the INPUT SEL. switch on the front panel to “DV”.

Set the BACKUP REC TIME item of the SYSTEM (1/2) menu.

Use the following settings according to the length of the tape of the source unit.

For DV or mini DV cassettes:

25MIN

: 30-minute tape

55MIN

: 60-minute tape

75MIN

: 80-minute tape

115MIN

: 120-minute tape

175MIN

: 180-minute tape

265MIN

: 270-minute tape

OFF

: No backup recording

Set the TC DUPLICATE item of the TIME CODE menu to “OFF”.

It records the data of the built-in time code generator or the built-in clock.

When the TC DUPLICATE menu item is set to “AUTO” or “NON DROP”, the time code of the DV camcorder will stop advancing. If the DV cable is disconnected, the time code of the backup recording will stop advancing.

Operation

1. Recording begins on the source unit.

*Please record from the beginning of the re- cording tape.

2.This unit begins recording when the tape of the source unit is near the end (about 5 minutes before the end of the tape).

• This unit begins recording when the record- ing time of the source unit reaches the time configured by the BACKUP REC TIME set- ting.

Memo

Backup recording records the video and sound from the source unit to the main unit.

While this unit is performing backup record- ing, please continue shooting from the source unit.

The audio mode is the mode configured in the source unit. (32K/48K)

Please set the BACKUP REC TIME item to “OFF” if the unit is not performing backup re- cording.

E-40