When an anomaly occurs, this unit automatically identifies the cause and displays an error- coded warning message on the monitor.
If the unit is in a state needing rectification, or if an operation error has occurred, an alarm display will be shown on the monitor.
| Warning display |
|
| Alarm display | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
3 2 K C H – 1 / 2 |
|
| S P 0 0 0 m i n |
| 3 2 K C H – 1 / 2 |
| S P 0 0 0 m i n | ||||
|
|
|
|
|
|
|
|
|
| ||
| W A R N I N G | 7 0 0 1 |
|
|
| H E A D C L E A N I N G R E Q U I R E D ! |
| ||||
| D R UM MO T O R F A I L U R E |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||||
1 0 / 1 0 / 0 2 |
|
| S T A N D B Y - O F F |
| 1 0 / 1 0 / 0 2 |
| S T A N D B Y - O F F | ||||
1 2 : 0 0 : 0 0 | T C R | 0 2 : 0 0 : 0 0 : 0 0 |
| 1 2 : 0 0 : 0 0 | T C R 0 2 : 0 0 : 0 0 : 0 0 | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
Alarm display (Displayed regardless of the DISPLAY mode)
Display | Status | Action | |
|
|
| |
LOW VOLTAGE | The DC power voltage is low. | Please check the power voltage. | |
|
| The unit will eventually go into the OPERATE |
|
|
| OFF mode if operation is continued. |
|
|
|
| |
HEAD CLEANING | The video head is dirty. If the head is clogged, it | Please clean it with the dedi- | |
REQUIRED! | will be detected and the alarm message will be | cated | |
|
| displayed during the PLAYBACK mode. When | (☞ Page 8) |
|
| the STOP mode is engaged or when the cas- | If the message persists despite |
|
| sette is ejected, the display will go off. | cleaning, it could be due to bad |
|
| When the head clog is cleared, the message | recording condition, bad tape or |
|
| will disappear. | lifespan of the head. |
|
|
| |
OVER HEATING! | The internal temperature of the unit has ex- | Please disconnect the power | |
|
| ceeded the regulated value. | and place the unit in a cool |
|
|
| place. If this message is dis- |
|
|
| played again, the unit may have |
|
|
| been damaged. Please consult |
|
|
| your JVC authorized dealer. |
|
|
|
|
UNPLUG | MAIN | This is a system error that occurs when the | Unplug the power cord from the |
POWER, | PLUG | power is turned on. The OPERATE indicator on | power outlet and wait for some |
BACK IN AFTER A | this unit blinks in green. The unit will not accept | time before plugging it back in. | |
WHILE |
| any operation commands. |
|
|
|
|
|
• For alarm displays resulting from operation errors, please refer to page 22.