20
A MODE
Terminal Name
AUTO
I/O 1 to 8
(I/O 9/ to 16/8)
UNIT ALARM
CAMERA SW
Condition
—
When 8 SEL OUT is set
•I/O 1 to 8 correspond to
cameras 1 to 8.
When 8 ALM OUT is set
•I/O 1 to 8 corresponds to
cameras 1 to 8.
—
—
Signals
The MAKE signal is output for between 500 ms and 1000 ms duration
in the following cases.
●Power OFF ➝ ON.
●AUTO SEQUENCE (AUTO button OFF → ON)
●When an AUTO SEQUENCE operation which has been interrupted
by an alarm input resumes.
The MAKE signal is output for between 500 ms and 1000 ms duration
from the terminal corresponding to the camera number in the follow-
ing cases.
●When AUTO SEQUENCE is turned OFF, the MAKE signal is output
to the Camera No. terminal corresponding to the camera displayed
on the camera indication.
●With AUTO SEQUENCE set to OFF, each time when the camera is
selected, the MAKE signal is output to the Camera No. terminal
corresponding to the camera selected.
●If an Alarm is input when AUTO SEQUENCE is activated, the MAKE
signal is output to the Camera No. terminal corresponding to the
camera to which the Alarm signal is input.
●If the PRIORITY item is set to ALARM, when there is an Alarm input
while AUTO SEQUENCE is OFF, the MAKE signal is output to the
Camera No. terminal corresponding to the camera to which the Alarm
signal is input.
The MAKE signal is output for between 500 ms and 1000 ms duration
in the following cases.
●The main signal is output at the terminal corresponding to the number
of the camera which sent the alarm signal.
The MAKE signal is output continuously throughout the alarm period.
The MONITOR OUTPUT 2 signal will be as follows, depending on the
setting of the "CAM SWITCH".
OFF : Same video signal as MONITOR OUTPUT 1, regardless of
the CAMERA SW terminal.
LOW : The camera’s video signal is switched at the next VD after the
falling signal from the time-lapse VCR is received.
HIGH : The camera video is switched at the next VD after the raising
signal from the time-lapse VCR is received.
4. CONNECTIONS
●The master monitor displays the video signal from the selected camera.
●Use the CAMERA SW input to switch the video signal and record it on the VCR.
●The preset operation, manual operation, AUTO PAN operation and AUTO PATROL operation are available for each camera.
●When fixed cameras are used, only the video signal can be switched.
●The alarm operation is available using the DATA I/O terminals.
●Alarms with up to 64 positions per camera can be handled via the SERIAL-1 connector.
In the A mode, in which the camera signals are input directly to the VIDEO INPUT connectors on the rear panel, the DATA I/O
terminals outputs as shown in the following table :