10
SYSTEM
RM-P2580 System
nSystem with up to 8 cameras
(Sixteen position settings available for each camera.)
• Confirm switch settings on the screen as follows.
qConfirm that the image from the camera to be
checked is displayed on the monitor.
wTurn OFF and then ON the AC 24 V power to the
camera to be checked.
eThe camera begins the initial operation and
characters similar to those shown in the illustration
on the right appear on the monitor screen.
rConfirm that “DUPLEX” and “ID- ” are displayed
and that the ID number is the correct number (the
number should be the same as the number of the
VIDEO INPUT terminal to which the camera is
connected on the rear panel of the RM-P2580).
tIf wrong, set the camera ID again.
MONITOR screen
(example showing camera ID as “05”)
“DUPLEX” should
be displayed. The number shown in
the □□ part of ID-□□
should be correct.
REC
PLAY
FFREW
REVERSEPAUSE/
STILL
REC
CHECK
STOP/EJECT
COUNT/
CLOCK
TIME
MODETIMER
REC AL/PL
RESET
MENU
VIDEO CASSETTE RECORDER
SHIFT/TRACKING
SET/V.LOCK
RESET
/CANCEL
OPERATE
SR-L910
OPE. LOCK
1
TO CAMERATO CAMERA DATA I / ODATA I / O
RXRX+
{
RX
-
|
TX+
{
TX
-
|
COMCOM
12 3 4 5 6 7 8
COMCOM
9/110/211/312/4 13/5 14/6 15/716/8
COMCOM COMCOM COMCOM
CAMERACAMERA
SW
UNIT
ALARM
AUTO
4312 8756
2 3 4 5 6 7 8
1
MONITOR
OUTPUTMONITOR
SERIAL-2SERIAL-1
VIDEO INPUT
VIDEO OUTPUT
OUTPUT
2
1
ON
2 3 4 5 6 7 8
POWER
OFF
ON
AC INPUT
‘
IN TIALI
PROT OOLDUPLEXID-05C
Camera
TK-AM200
Camera
TK-AM200
Camera
TK-AM200
Camera 1
Camera 2
Camera 8
Camera ID: 01
Termination: OFF
Camera ID: 02
Termination: OFF
Camera ID: 08
Termination: ON
Control signal cable
Video signal cable
Power cable
Remote Control Unit
RM-P2580
Time lapse VCR MONITOR
MONITOR
AC24V
AC24V
AC24V
CAM SW
OUT
VIDEO IN
COM
CAMERA
SW
TO
CAMERA
MONITOR
OUTPUT 2
MONITOR
OUTPUT 1
Memo:
• When operating a system using the RM-P2580, several cameras (up to 8) can be connected and
used on one control signal cable. Consequently, an incorrect s witch setting on just a single camera
will cause the entire system to work incorrectly.