Introduction

mDisclaimer

vWe will not be responsible for any inconveniences or disturbances caused in the event of privacy invasion as a result of camera footages of this product.

mOthers

vWhen using this camera with [AGC] set to "MID" or "HIGH", the sensitivity increases automatically for dark images and the screen may appear grainy, but this is not a malfunction.

vIf the DAY/NIGHT switch is turned to "AUTO", the mode changes automatically to black and white in dark places. As the sensitivity level is increased in this case, the screen may appear grainy and more white spots may appear. When switching between modes, the brighter area on the screen is emphasized and visibility may be reduced. However, this is not a malfunction.

vWhen shooting an extremely bright object (e.g. lamp), the image on the screen may have white vertical tailings (smear) or expansion (blooming) may appear around it. This is a characteristic of the CCD and not a malfunction.

vWhen the white balance of this camera is set to "ATW-N" or "ATW-W" and depending on the conditions of the object, the color tone may differ slightly from the actual color due to the principle of the automatic tracking white balance circuit. This is not a malfunction.

vWhen this camera is used under high temperatures, vertical stripes may appear on the screen. This is a characteristic of the CCD and not a malfunction.

vWhen this camera is moved from a cold to warm place, condensation may occur and the camera may not work. In this case, leave the camera under room temperature for about one hour before turning on the power.

vWhen the power supply voltage is momentarily disrupted or drops due to lightning, turning on the air-conditioner or the like, image distortion or noise may occur.

vWhen the power supply voltage of the camera drops, the input protection circuit

inside the camera operates, and the camera may be turned off. Make use of a

voltage rating within 10 % for the camera’s power supply voltage. 5

vThis unit enlarges the rotation angle to support wide range set up. When the

zoom of the lens is set to WIDE end and the tilt angle is set around 80 , a part 5 7

of this camera appears in the image depending on the rotation angle. In this case, adjust the image angle if necessary. (A page 24)

vTo prevent fogging resulting from temperature changes, be sure to insert the silica gel at the location specified. (A page 16)

vThe 3D noise reduction function of this camera may result in afterimage of a moving subject. Afterimage is more likely to occur when using the camera with [DNR LEVEL] set to "HIGH". This is not a malfunction.

5