A Mail Settings

 

For setting the mail options when [Mail] is selected as the action on the

 

(VN-H57U/H257U/

 

Alarm page. If an SMTP server, a port number or a sender's mail

 

H257VPU/H157WPU

 

address has been set, "Preset" will be displayed.

 

only)

 

 

 

 

 

 

 

 

 

SMTP Server

 

Sets the IP address or FQDN of the SMTP server.

 

 

 

Memo:

 

 

 

 

 

 

 

 

 

FQDN (Fully Qualified Domain Name)

 

 

 

This refers to a domain name that has been completely specified, without

 

 

 

abbreviation of the host or domain names on a TCP/IP network.

 

 

 

For example, with a host name of www and a domain name of

 

 

 

victor.co.jp, the FQDN representation is "www.victor.co.jp".

 

 

 

Japanese cannot be used in a FQDN. If you have configured an FQDN,

 

 

 

configure a DNS server on the Network Basic page as well. (A Page 59)

 

 

 

 

 

 

 

 

 

 

Port Number

 

Enter the port number.

 

 

 

[Set values: 0 - 110 - 65535]

 

 

 

 

 

Send Mail Address

 

Set the sender's mail address.

 

 

 

 

 

 

POP To enable [POP before SMTP], select "Enable" and set up the POP server.

before POP Sets the IP address or FQDN of the POP server.

SMTP Server

 

 

Port

Enter the port number.

 

 

Number

[Set values: 0 - 110 - 65535]

 

 

 

 

 

 

User

Enters a user name.

 

 

Name

 

 

 

 

 

 

 

Password

Enters a password.

 

 

B Alarm output

Configure settings related to alarm output from an alarm output cable or

 

 

 

connector.

 

 

 

 

 

Duration

Sets the output duration for [Manual Output].

 

[Set values: 0/ 100 - 1000 - 5000] msec

 

 

 

 

 

 

 

 

 

 

Manually operate alarm output.

 

 

 

The current output status is displayed on the right side. When [Duration]

 

 

 

is set to "0", pressing the [Make] button sets the alarm to make output,

 

 

 

and pressing the [Break] button sets the alarm to break output.

 

Manual Output

When [Duration] is set to other than "0", pressing the [Make] button sets

 

the alarm to make output only for the output duration time, and then

 

 

 

 

 

 

changes it to break output.

 

 

 

When [Duration] is set to other than "0", pressing the [Break] button sets

 

 

 

the alarm to break output only for the output duration time, and then

 

 

 

changes it to make output.

 

 

 

 

 

 

 

* The [Set values] in bold letters are factory defaults.

41