A Action | For specifying the type of action. |
| ||
| Disable | : Does not trigger any action. |
| |
| : Sends out |
| ||
|
|
| The title of the mail will appear as [Alarm from |
|
|
|
| and the sender as [Camera ID]. Enter the message to send |
|
|
|
| in [Mail Text]. Input up to 127 alphanumeric characters. |
|
|
|
| To attach the latest image to the mail, set [Attach Image] to |
|
|
|
| AOnB. |
|
| FTP | : Sends out |
| |
|
|
| page on Alarm Environment for details on |
|
|
|
|
| |
|
|
| The maximum transmission rate of FTP is 1 Mbps. If a new |
|
|
|
| FTP trigger occurs during |
|
|
|
| portion is treated as |
|
|
|
| recording starts. During FTP transmission after completing |
|
|
|
| the |
|
|
|
| FTP trigger occurs. |
|
| TCP | : Sends out the character string entered in the [TCP/UDP |
| |
|
|
| Data] field to the destinations specified in [TCP/UDP IP |
|
|
|
| Address] and [TCP/UDP Port Number] via TCP. |
|
| UDP | : Sends out the character string entered in the [TCP/UDP |
| |
|
|
| Data] field to the destinations specified in [TCP/UDP IP |
|
|
|
| Address] and [TCP/UDP Port Number] via UDP. |
|
| TCP/UDP Data | : Input up to 127 alphanumeric characters. |
| |
| Output 1 Make | : Changes Alarm Output 1 to Make. |
| |
| Output 2 Make | : Changes Alarm Output 2 to Make. |
| |
| Output 1 Break | : Changes Alarm Output 1 to Break. |
| |
| Output 2 Break | : Changes Alarm Output 2 to Break. |
| |
|
|
| Set the alarm output time in the [Alarm Output Duration] |
|
|
|
| field. |
|
|
|
| ||
B 1st Trigger | For specifying the first trigger to be activated. |
| ||
| Either alarm input (make), alarm input (break) or motion detection can be |
| ||
| selected. |
|
| |
| Note: |
|
|
|
|
|
|
| |
| ● When the second trigger is turned off, the action will be invoked only by |
| ||
| the first trigger. |
| ||
| ● When motion detection is selected as the first trigger, selection of AMax. |
| ||
| IntervalB and A2nd TriggerB will be disabled. |
| ||
|
|
| ||
C Max. Interval | Enabled when both the first and second triggers are specified. |
| ||
| Specify the maximum interval between the first and second triggers. An |
| ||
| action will be invoked only if the interval between the first and second |
| ||
| triggers is within the maximum interval. |
| ||
|
|
| ||
D 2nd Trigger | For specifying the second trigger for invoking an action. |
| ||
| Either alarm input (make) or alarm input (break) can be selected. Unlike the |
| ||
| first trigger, motion detection is not available as an option. |
| ||
|
|
|
|
|
43