A Action

For specifying the type of action.

 

 

Disable

: Does not trigger any action.

 

 

Mail

: Sends out e-mail. Specify the recipient’s mail address.

 

 

 

 

The title of the mail will appear as [Alarm from VN-V2x]

 

 

 

 

and the sender as [Camera ID]. Enter the message to send

 

 

 

 

in [Mail Text]. Input up to 127 alphanumeric characters.

 

 

 

 

To attach the latest image to the mail, set [Attach Image] to

 

 

 

 

AOnB.

 

 

FTP

: Sends out pre-/post-recorded JPEG files via FTP. See the

 

 

 

 

page on Alarm Environment for details on pre-/post-

 

 

 

 

recording and FTP server settings. (A Page 46)

 

 

 

 

The maximum transmission rate of FTP is 1 Mbps. If a new

 

 

 

 

FTP trigger occurs during post-recording, the recorded

 

 

 

 

portion is treated as pre-recording and a new post-

 

 

 

 

recording starts. During FTP transmission after completing

 

 

 

 

the post-recording, a new post-recording starts if a new

 

 

 

 

FTP trigger occurs.

 

 

TCP

: Sends out the character string entered in the [TCP/UDP

 

 

 

 

Data] field to the destinations specified in [TCP/UDP IP

 

 

 

 

Address] and [TCP/UDP Port Number] via TCP.

 

 

UDP

: Sends out the character string entered in the [TCP/UDP

 

 

 

 

Data] field to the destinations specified in [TCP/UDP IP

 

 

 

 

Address] and [TCP/UDP Port Number] via UDP.

 

 

TCP/UDP Data

: Input up to 127 alphanumeric characters.

 

 

Output 1 Make

: Changes Alarm Output 1 to Make.

 

 

Output 2 Make

: Changes Alarm Output 2 to Make.

 

 

Output 1 Break

: Changes Alarm Output 1 to Break.

 

 

Output 2 Break

: Changes Alarm Output 2 to Break.

 

 

 

 

Set the alarm output time in the [Alarm Output Duration]

 

 

 

 

field.

 

 

 

 

B 1st Trigger

For specifying the first trigger to be activated.

 

 

Either alarm input (make), alarm input (break) or motion detection can be

 

 

selected.

 

 

 

Note:

 

 

 

 

 

 

 

 

When the second trigger is turned off, the action will be invoked only by

 

 

the first trigger.

 

 

When motion detection is selected as the first trigger, selection of AMax.

 

 

IntervalB and A2nd TriggerB will be disabled.

 

 

 

 

C Max. Interval

Enabled when both the first and second triggers are specified.

 

 

Specify the maximum interval between the first and second triggers. An

 

 

action will be invoked only if the interval between the first and second

 

 

triggers is within the maximum interval.

 

 

 

 

D 2nd Trigger

For specifying the second trigger for invoking an action.

 

 

Either alarm input (make) or alarm input (break) can be selected. Unlike the

 

 

first trigger, motion detection is not available as an option.

 

 

 

 

 

 

43