A Action

For specifying the type of action.

 

Disable

: Does not trigger any action.

 

Mail

: Sends out e-mail. Specify the recipient’s mail address. The title

 

 

of the mail will appear as [Alarm from VN-X35U] and the sender

 

 

as [Camera ID]. Enter the message to send in [Mail Text]. Input

 

 

up to 127 alphanumeric characters. To attach the latest image

 

 

to the mail, set [Attach Image] to AOnB.

 

FTP

: Sends out pre-/post-recorded JPEG files via FTP. See the page

 

 

on Alarm Environment for details on pre-/post-recording and

 

 

FTP server settings. (A Page 54)

 

 

The maximum transmission rate of FTP is 1 Mbps. If a new FTP

 

 

trigger occurs during post-recording, the recorded portion is

 

 

treated as pre-recording and a new post-recording starts.

 

 

During FTP transmission after completing the post-recording, a

 

 

new post-recording starts if a new FTP trigger occurs.

 

TCP

: Sends out the character string entered in the [TCP/UDP Data]

 

 

field to the destinations specified in [TCP/UDP IP Address] and

 

 

[TCP/UDP Port Number] via TCP.

 

UDP

: Sends out the character string entered in the [TCP/UDP Data]

 

 

field to the destinations specified in [TCP/UDP IP Address] and

 

 

[TCP/UDP Port Number] via UDP.

 

TCP/UDP Data

: Input up to 127 alphanumeric characters.

 

Output 1 Make

: Changes Alarm Output 1 to Make.

 

Output 1 Break

: Changes Alarm Output 1 to Break.

 

Output 2 Make

: Changes Alarm Output 2 to Make.

 

Output 2 Break

: Changes Alarm Output 2 to Break.

 

 

 

Set the alarm output time in the [Alarm Output Duration]

 

 

 

field.

 

Position

: Moves to the preset position specified in the Action Position No.

 

 

item E. (A Page 53)

 

Play Audio : Play back an Audio File registered on VN-X35U. (A Page 49)

 

 

B 1st Trigger

For specifying the first trigger to be activated.

 

[Set values:Input 1 Make, Input 2 Make, Input 1 Break, Input 2 Break,

 

Motion detection, Position]

Memo:

When the second trigger is turned off, the action will be invoked only by the first trigger.

If [Motion detection] or [Position] is selected as the first trigger, [Max.Interval] and [2nd Trigger] cannot be selected..

51