Kenmore 795.775646 manual Pin10 WH Pin4 BL Resistance Test Point Ressult, Open or Short of Fuse-M

Models: 795.775626 795.775696 795.775726 795.775736 795.775646 795.775636 795.775796

1 78
Download 78 pages 19.02 Kb
Page 23
Image 23

Is the resistance value

Yes

Normal

between pins 10(WH)

 

 

And 4(BL) of CON3

 

 

 

 

like as below?

 

 

 

 

 

 

 

 

pin10 WH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pin4 BL

 

 

 

 

 

 

 

 

 

 

Resistance

 

 

 

 

 

 

 

 

 

 

Test Point

 

 

 

Ressult

 

 

 

 

 

 

 

 

 

(1) To (2)

 

34 ~ 42 Ω

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

Is the connection loose?

 

 

 

 

 

 

 

 

Yes

 

Reconnect

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

Is the resistance value

No

Replace

Fuse-M

of Fuse –M like

 

 

 

 

 

as below?

 

 

(1)BL

(2)BN

Open or Short of Fuse-M

Test Point

Ressult

 

 

(1) To (2)

0 Ω

 

 

Yes

Is the resistance value of

No

Replace

Heater

heater like as below?

 

 

 

 

 

 

(1) (2)

 

 

Heater Resistance

 

 

 

 

 

 

 

 

Test Point

 

Ressult

 

 

 

 

 

 

 

 

 

(1) To (2)

 

34 ~ 42 Ω

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

Is the resistance

No

Replace

DEF-sensor

value of DEF-sensor like

 

 

 

 

as below? It depends on

 

 

 

the temperature.

 

 

 

 

 

 

 

 

 

(1) BO

 

 

 

 

 

 

 

 

 

 

 

 

(2) BO

Defrost Sensor Resistance

 

 

 

 

 

 

 

 

 

Test Point

Result

Test Point

 

Result

 

 

 

 

 

 

 

-30°C

129.3 kΩ

10°C

 

19.53 kΩ

 

 

 

 

 

 

 

-20°C

76.96 kΩ

20°C

 

13.03 kΩ

 

 

 

 

 

 

 

-10°C

47.34 kΩ

30°C

 

8.896 kΩ

 

 

 

 

 

 

 

0°C

30 kΩ

40°C

 

6.201 kΩ

 

 

 

 

 

 

 

Yes

Explain to the customer! :

It can be occurred, when the gasket is not stuck to product or when you put the high temperature loads (hot foods) a lot

in the product.

- 23 -

Page 23
Image 23
Kenmore 795.775646, 795.775796 manual Pin10 WH Pin4 BL Resistance Test Point Ressult, Is the connection loose? Yes Reconnect