Service bulletin no. 7
No ALC - Drive 10 meters: Check for loose contact at oscillator wafer on coil pack.
No TX any band: Check the T1 on generator board
No TX: Bad driver FET Q1 3SK22(GR) on
No relay action when TX: Bad Q8 2SA562(Y). When replacing Q8 change resistor R16 to 4.7 ohm.
Rubber belt sliping on drive and load: TKC has Chain Modification Kit.
No drive when shock: Check for loose output terminals af final rotary switch
No output on any band: Check T2 GEN unit
No TX: Check final relay for burned contacts.
Bias current too high and blows fuse: Check for bad
Cannot neutralize: Make sure shield is properly installed on driver 12BY7.
No output from generator unit
No 9 Volt out at AVR
Low output power: If American 12BY7 is used in driver circuit, this can cause parasitic oscillation. Please use standard Kenwood replacement tubes.
Blows fuse: Check for shorted electrlytics at power supply
AC hum on SSB transmission: Send for TKC bulletin.