Problem

 

Probable Cause

 

Corrective Action

Ref. Page

 

 

 

 

 

 

 

 

You cannot transmit by

1

You selected a frequency outside

1

Select a frequency within the

7

 

pressing the PTT

 

the allowable transmit frequency

 

allowable transmit frequency range.

 

 

switch.

 

range.

 

 

 

 

 

2

You selected a transmit offset that

2

Press [F], [MHz] repeatedly so neither

21

 

 

 

places the transmit frequency

 

“+” nor “–” is visible.

 

 

 

 

outside the allowable range.

 

 

 

 

 

3

TX Inhibit is ON.

3

Access Menu 1–5–5 and select “OFF”.

51

 

 

4

Tone Alert is ON.

4

Press [F], [ENT] to switch OFF Tone

47

 

 

 

 

 

Alert.

 

 

 

5

Packet data was being transmitted

5

Press the PTT switch after transmitting

 

 

 

using the data band.

 

of packet data is completed.

 

 

 

 

 

 

 

The transceiver

The Automatic Power Off (APO)

Switch OFF the APO function.

49

 

switches OFF for no

function is ON.

 

 

 

 

apparent reason.

 

 

 

 

 

 

 

 

 

 

 

Turning the VOL control

The speaker for the band you wanted

Press [BAL], then [UP]/ [DWN] to

48

 

does not allow you to

to monitor was muted.

correctly adjust the volume balance

 

 

hear audio.

 

 

between the two bands.

 

 

Packet operation results

1

The squelch is open.

1

Select the correct squelch level so that

8

 

in no connects with

 

 

 

the squelch is opened only when

 

 

other stations.

 

 

 

signals are present.

 

 

 

2

You did not select the same

2

Use HBAUD command to select the

54

 

 

 

transfer rate as the target station.

 

appropriate transfer rate.

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

91