HEARTH PRODUCTS KITS AND ACCESSORIES
750,206M
REV. NC 03/2006
Cat. No. | Model | Description |
H3991 |
| OUTSIDE AIR GATE & DUCT KIT |
INSTALLATION INSTRUCTIONS FOR OUTSIDE COMBUSTION AIR GATE KIT FOR USE WITH
|
| KIT CONTENTS |
|
| |
ITEM | QUANTITY | DESCRIPTION |
|
| |
1 | 1 ea. | Air Gate Assembly |
|
| |
2 | 1 ea. | Arm, Air Gate |
|
| |
3 | 1 ea. | Bracket, Air Gate Arm |
|
| |
4 | 1 ea. | Collar, Outside Air |
|
| |
5 | 1 ea. | Duct, 4” |
|
|
|
6 | 1 ea. | Hardware Kit (9 long screws & 4 short screws) |
| ||
7 | 1 ea. | Instruction Sheet |
|
| |
Table 1 - Refer to Figure 1 |
|
|
| ||
| 6 |
|
| 5 | 1 |
| 1 |
|
|
|
|
|
|
|
| 7 |
|
| 2 |
| 4 | 3 |
|
|
|
|
| ||
Figure 1 - Kit Contents (see Table 1) |
|
| |||
TOOLS / SUPPLIES REQUIRED |
|
|
| ||
• 5/16” Nut driver or Socket | • Duct Tape | • Silicon Type Caulking |
GENERAL INFORMATION
This kit is for use with models
These kits have an air gate assembly which allows adjustment of the amount of outside air delivered to the fire for combustion. Only one air kit, located on the right side of the firebox, is required.
If you encounter any problems, need clarification of these instructions or are not qualified to properly install this kit, contact you local distributor or dealer.
Retain These Instructions for Future Reference
INSTALLATION INSTRUCTIONS
1. Remove the outside air
2. Assemble the Air Gate as shown in Figures 3 & 4.
3. Take the Air Gate Assembly and feed the arm through the round opening (see Figures 5 & 6) and then through the side frame opening. Ensure the air gate arm remains attached to the air gate (see Figure 7).
WARNING
Do not operate the combustion air gate with a fire in the firebox unless all components of this kit have been installed.
|
| Side View of Arm |
Right Hand Side |
| installed into Air |
| Gate. | |
of Firebox |
| |
|
| |
Remove Outside | Air Gate Assembly | |
|
| |
Air |
|
|
Air Gate Arm
Figure 2 | Figure 3 |
Air Gate Arm
Air Gate
Outside View of Arm installed into Air Gate.
Figure 4 | When assembled onto appliance, the notch |
here must be positioned down as shown. |
Air Gate
Air Gate Arm
Right Side
Panel on
Firebox
Figure 5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. | 1 |