MODEL NO. | CI1500DVF Series |
| MODEL NO. | CI2500DVF Series | ||||||||||||
|
|
|
|
|
|
|
|
| MANUFACTURED AT: |
| Burlington, WA | |||||
MANUFACTURED AT: |
| Burlington, WA |
|
| ||||||||||||
|
|
|
|
|
|
|
|
| FOR USE WITH NATURAL GAS. |
|
| EQUIPE POUR GAZ NATUREL | ||||
FOR USE WITH NATURAL GAS. |
|
| EQUIPE POUR GAZ NATUREL |
|
| |||||||||||
ALTITUDE |
|
|
|
| ALTITUDE |
|
|
| ||||||||
MIN. GAS SUPPLY PRESS (“WC) |
|
|
|
|
|
| MIN. GAS SUPPLY PRESS (“WC) |
|
|
|
| 4.5” | ||||
PRESS MIN. D’ALIMENTATION (“CE) |
|
|
|
| 4.5” |
| PRESS MIN. D’ALIMENTATION (“CE) |
|
|
|
| |||||
MANIFOLD PRESSURE (“WC) |
|
|
|
|
|
| MANIFOLD PRESSURE (“WC) |
|
|
|
| 3.5” | ||||
PRESSION CE TUBULURE (“CE) |
|
|
|
| 3.5” |
| PRESSION CE TUBULURE (“CE) |
|
|
|
| |||||
MANUFACTURER’S RECOMMENDED ORIFICE SIZE |
|
|
| MANUFACTURER’S RECOMMENDED ORIFICE SIZE | .121 | |||||||||||
DIMENSION DE L’INJECTEUR RECOMMANDE PAR | #37 |
| DIMENSION DE L’INJECTEUR RECOMMANDE PAR | |||||||||||||
MANUFACTURIER (DMS) |
|
|
|
|
|
|
| MANUFACTURIER (DMS) |
|
|
|
|
|
| ||
MAX INPUT (BTUH) |
|
|
|
|
|
|
| MAX INPUT (BTUH) |
|
|
|
| 38,500 | |||
ENTRÉE MAX (BTUH) |
|
|
|
| 28,000 |
| ENTRÉE MAX (BTUH) |
|
|
|
| |||||
MIN INPUT (BTUH) |
|
|
|
|
|
|
| MIN INPUT (BTUH) |
|
|
|
|
|
| ||
ENTRÉE MIN (BTUH) |
|
|
|
| 17,500 |
| ENTRÉE MIN (BTUH) |
|
|
|
| 25,500 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
ELECTRICAL RATING/EXIGENCES ELECTRIQUES: |
|
|
|
|
|
|
|
|
| |||||||
| ELECTRICAL RATING/EXIGENCES ELECTRIQUES: | |||||||||||||||
OPTIONAL FAN/SOUFFLEUR OPTIONAL |
|
| 1 ph |
|
|
| ||||||||||
|
|
|
|
| OPTIONAL FAN/SOUFFLEUR OPTIONAL |
|
| 1 ph |
|
| ||||||
|
|
|
|
| 60 HZ |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| 60 HZ |
|
| |
|
|
|
|
| 120 VOLTS |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| 120 VOLTS |
|
| |
|
|
|
|
| LESS THAN 5 AMPS |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| LESS THAN 5 AMPS | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
MINIMUM |
|
| SIDEWALLS |
| 2” |
| MINIMUM |
|
| SIDEWALLS |
| 2” | ||||
|
|
|
| FLOOR |
| 0” |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| FLOOR |
| 0” | ||||
CLEARANCES TO |
| CEILING OR ALCOVE HEIGHT |
| 62” |
|
|
|
|
|
| ||||||
|
|
| CLEARANCES TO |
| CEILING OR ALCOVE HEIGHT |
| 62” | |||||||||
|
| BACK/CORNER 45° |
| 4” |
|
|
| |||||||||
|
|
|
|
|
| BACK/CORNER 45° |
| 4” | ||||||||
COMBUSTIBLE |
| VENT SURFACES: TOP |
| 3” |
|
|
|
| ||||||||
|
|
| COMBUSTIBLE |
| VENT SURFACES: TOP |
| 3” | |||||||||
|
|
|
|
| SIDES |
| 1” |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| SIDES |
| 1” | ||
MATERIAL |
|
|
|
| BOTTOM |
| 1” |
|
|
|
|
|
|
| ||
|
|
|
|
|
| MATERIAL |
|
|
|
| BOTTOM |
| 1” | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| ALCOVE MAXIMUM DEPTH |
| 48” |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| ALCOVE MAXIMUM DEPTH |
| 48” | ||||||||
DEGAGEMENT |
| MUR ADJACENTS |
| 50.8mm |
|
|
|
| ||||||||
|
|
| DEGAGEMENT |
| MUR ADJACENTS |
| 50.8mm | |||||||||
|
|
| PLANCHER |
| 0mm |
|
|
|
| PLANCHER |
| 0mm | ||||
MINIMUM DE |
| PLAFOND OU HAUTEUR D'ALCÔVE |
| 1574.8mm |
| MINIMUM DE |
| PLAFOND OU HAUTEUR D'ALCÔVE |
| 1574.8mm | ||||||
|
| EN ARRIÈRE ET COIN 45 ANGLE |
| 101.6mm |
|
|
| EN ARRIÈRE ET COIN 45 ANGLE |
| 101.6mm | ||||||
MATERIAUX |
| SURFACES D’AERATION: DESSUS |
| 76.2mm |
| MATERIAUX |
| SURFACES D’AERATION: DESSUS |
| 76.2mm | ||||||
|
|
|
|
| COTES |
| 25.4mm |
|
|
|
|
|
| COTES |
| 25.4mm |
COMBUSTIBLES |
|
|
|
| BAS |
| 25.4mm |
| COMBUSTIBLES |
|
|
|
| BAS |
| 25.4mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| PROFONDEUR D'ALCÔVE MAXIMALE |
| 1219.2mm |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| PROFONDEUR D'ALCÔVE MAXIMALE |
| 1219.2mm | ||||||||
DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE |
|
|
|
| ||||||||||||
| DIRECT VENT GAS STOVE / APPAREIL A GAZ AVEC EVACUATION DIRECTE | |||||||||||||||
VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL. |
| VENTED GAS STOVE HEATER – NOT FOR USE WITH SOLID FUEL. | ||||||||||||||
FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN |
| FOYER DE CHAUFFAGE AU GAZ A EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN | ||||||||||||||
|
| COMBUSTIBLE SOLIDE. |
|
|
|
|
| COMBUSTIBLE SOLIDE. |
|
| ||||||
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY. |
| FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY. | ||||||||||||||
N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL. |
| N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL. | ||||||||||||||
“CAUTION: Do not operate the appliance with glass removed, cracked or broken. |
| “CAUTION: Do not operate the appliance with glass removed, cracked or broken. | ||||||||||||||
Replacement of panel should be done by a licensed or qualified service person.” |
| Replacement of panel should be done by a licensed or qualified service person.” .” | ||||||||||||||
“This appliance is equipped at the factory for use with natural gas only. Units using |
| “This appliance is equipped at the factory for use with natural gas only. Units using | ||||||||||||||
propane must be field converted using the LP conversion kit, P/N |
| propane must be field converted using the LP conversion kit, P/N | ||||||||||||||
FINAL INSPECTION BY: |
|
|
|
|
|
| FINAL INSPECTION BY: |
|
|
|
|
| ||||
|
| ANSI Z21 |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| ANSI Z21 |
|
| |||||||
|
| CSA |
|
|
|
|
| CSA |
|
| ||||||
|
|
|
|
|
|
|
|
|
VENTED GAS STOVE HEATERS |
| VENTED GAS STOVE HEATERS |
FOYER DE CHAUFFAGE AU GAZ A EVACUATION P/N |
| FOYER DE CHAUFFAGE AU GAZ A EVACUATION P/N |
|
|
|
SERIAL NUMBER/NOMBRE DE SERIE |
| SERIAL NUMBER/NOMBRE DE SERIE |
XXXXX XXXXX |
| XXXXX XXXXX |
| |
IIIIIIIIIIIIIIIIIIII |
| IIIIIIIIIIIIIIIIIIII |
| |
XXXXXXXXXXXXXXXX |
| XXXXXXXXXXXXXXXX |
| |
P/N |
| P/N | 17 | |