In selecting this LENNOX
Please carefully read and follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your LENNOX product.
Note: Installation and repair should be performed by a qualified service person. The appliance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean.
TABLE OF CONTENTS |
|
|
Introduction ...................................... | page | 2 |
General Information .......................... | page | 2 |
Operation/Care of Your Appliance ..... | page | 3 |
Gas Controls/Control Compartment, |
|
|
Access ............................................ | page | 4 |
Variable Flame Adjustment ............... | page | 5 |
Outside Combustion Air Control ....... | page | 5 |
Venting Action and Safety Limit ........ | page | 5 |
Maintenance ..................................... | page | 6 |
Front Glass Enclosure Panel, |
|
|
Removal and Installation ................ | page | 6 |
Maintenance Schedule ...................... | page | 7 |
Burner Adjustments .......................... | page | 8 |
Log Placement .................................. | page | 9 |
Vermiculite and Black/Gray Ceramic |
|
|
Fiber Chunks Placement ................ | page | 9 |
Millivolt Appliance Checkout ............. | page | 9 |
Electronic Appliance Checkout .......... | page 10 | |
Wiring Diagrams ............................... | page 10 | |
Warranty ........................................... | page 10 | |
Replacement Parts ............................ | page 10 | |
Product Reference Information ........ | page 10 | |
Accessory Components .................... | page 11 | |
Lighting Instructions – Millivolt ........ | page 16 | |
Lighting Instructions – Electronic ..... | page 18 | |
Troubleshooting Guide – Millivolt ...... | page 20 | |
Troubleshooting Guide – Electronic ... | page 21 | |
Replacement Parts List ...................... | page 23 |
The millivolt appliances are designed to operate on either natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient operation. If any optional accessories which require electrical power are being installed, the electrical power must be provided at the time of appliance installation.
The electronic appliances are designed to operate on either natural or propane gas. An electronic intermittent pilot system provides safe, efficient operation. External electrical power is required to operate these units.
These appliances comply with National Safety Standards and are tested and listed by Omni- Test Laboratories (Report No.
Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54). (In Canada, the current CAN/CGA B149 installation code.) Electrical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA 70 - (latest edition). (In Canada, the current CSA C22.1 Canadian Electric Code.)
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les instructions d'installation et d'utilisation qui accompagnent l'appareil.
Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.
Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. Locate furniture and window coverings accordingly.
WARNING: THESE FIREPLACES ARE VENTED DECORATIVE GAS APPLIANCES. DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES.
These appliances are designed to operate on natural or propane gas only.Input of millivolt models is shown in the following table:
Millivolt ModelsNatural and Propane | Input rate (BTU/H) |
Gas Models | |
EBVSTNM, EBVPFNM, | 30,000 TO 37,500 |
EBVSTPM, EBVPFPM, | 27,000 TO 34,000 |
EBVCLNM, EBVCRNM, | 28,000 TO 34,000 |
EBVCLPM, EBVCRPM | 27,000 TO 34,000 |
Input of electronic models is shown in the following table:
Electronic ModelsInput rate (BTU/H)Natural Gas ModelsFixed RateEBVSTNE, EBVPFNE, | 37,500 |
EBVCLNE, EBVCRNE, | 34,000 |