NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
SAFETY / LISTING LABELS - MODELS: EDVI30 & EDVI35
MODEL NO. EDVI35
MANUFACTURED AT: Union City, TN FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE MIN. GAS SUPPLY PRESS (“WC) PRESS MIN. D’ALIMENTATION (“CE) MANIFOLD PRESSURE (“WC) PRESSION CE TUBULURE (“CE) MANUFACTURER’S RECOMMENDED ORIFICE SIZE DIMENSION DE L’INJECTEUR RECOMMANDE PAR MANUFACTURIER (DMS) MAX INPUT (BTU/HR) ENTREE MAX MIN INPUT (BTU/HR) ENTREE MIN0-4500 FT/PI (0-1370M) 4.5” 3.5” #33 35,000 25,500
ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
-UNIT/APPAREIL: MILIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS
MINIMUM SIDEWALL
FLOOR
8”
0”
CLEARANCES TO CEILING (FROM BOTTOM OF UNIT) 64”
COMBUSTIBLE
MATERIAL
MANTEL FROM TOP OF UNIT
18”
MANTEL DEPTH
DEGAGEMENT MUR ADJACENTS
PLANCHER 0mm
MINIMUM DE
PLAFOND (DU BAS DE L’APPAREIL) 1626mm
MATERIAUX
COMBUSTIBLES MANTEAU 457mm
PROFONDEUR DU MANTEAU
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL. FOR INSTALLATION
IN SOLID FUEL FIREPLACES. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE
WITH AIR FILTERS.
FOYER AU GAZ CHAUFFANT AVEC EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN
COMBUSTIBLE SOLIDE. DOIT ETRE INSTALLE DANS UNE CHEMINEE EXISTANTE QUI
BRULE LE COMBUSTIBLE SOLIDE. NE PAS UTILISER DE FILTRE A AIR AVEC CE FOYER AU
GAZ A EVACUATION.
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.
N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL.
“CAUTION:
Do not operate the appliance with glass removed, cracked or broken. Replacement of panel should be done by a licensed or qualified service person.” “This appliance is equipped at the factory for use with natural gas only. Units using propane must be field converted using t he LP conversion kit,
FINAL INSPECTION BY:
ANSI Z21.88-2002 CSA 2.33-2002 CAN/CGA 2.17-M91 VENTED GAS FIREPLACE HEATER FOYERA AU GAZ CHAUFFANT AVEC EVACUATION P/N 9-1467B SERIAL NUMBER/NOMBRE DE SERIE XXX XXX

IIIIIIIIIIIIIIIIIIII

XXX P/N 9-1467B
DU DESSUS DE L'APPAREIL
12”
203mm
305mm
Cat. No. H0921.
(MAX)
(MAX)

MODEL NO. EDVI30

MANUFACTURED AT: Union City, TN FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE MIN. GAS SUPPLY PRESS (“WC) PRESS MIN. D’ALIMENTATION (“CE) MANIFOLD PRESSURE (“WC) PRESSION CE TUBULURE (“CE) MANUFACTURER’S RECOMMENDED ORIFICE SIZE DIMENSION DE L’INJECTEUR RECOMMANDE PAR MANUFACTURIER (DMS) MAX INPUT (BTU/HR) ENTREE MAX MIN INPUT (BTU/HR) ENTREE MIN 0-4500 FT/PI (0-1370M) 4.5” 3.5” #37 30,000 21,500
ELECTRICAL RATING/EXIGENCES ELECTRIQUES:
-UNIT/APPAREIL: MILIVOLT
1 ph
60 HZ
120 VOLTS
LESS THAN 5 AMPS
MINIMUM SIDEWALL
FLOOR
8”
0”
CLEARANCES TO CEILING (FROM BOTTOM OF UNIT) 64”
COMBUSTIBLE
MATERIAL
MANTEL FROM TOP OF UNIT
18”
MANTEL (MAX) 12”
DEGAGEMENT MUR ADJACENTS
PLANCHER
203mm
0mm
MINIMUM DE
PLAFOND (DU BAS DE L’APPAREIL) 1626mm
MATERIAUX
COMBUSTIBLES 457mm
PROFONDEUR DU MANTEAU 305mm
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL. FOR INSTALLATION
IN SOLID FUEL FIREPLACES. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE
WITH AIR FILTERS.
FOYER AU GAZ CHAUFFANT AVEC EVACUATION - NE DOIT PAS ETRE UTILISE AVEC UN
COMBUSTIBLE SOLIDE. DOIT ETRE INSTALLE DANS UNE CHEMINEE EXISTANTE QUI
BRULE LE COMBUSTIBLE SOLIDE. NE PAS UTILISER DE FILTRE A AIR AVEC CE FOYER AU
GAZ A EVACUATION.
FOR USE WITH GLASS DOOR CERTIFIED WITH THE APPLIANCE ONLY.
N’UTILISER SEULEMENT QUE LA PORTE DE VERRE CERTIFIE AVEC L’APPAREIL.
“CAUTION: Do not operate the appliance with glass removed, cracked or broken.
Replacement of panel should be done by a licensed or qualified service person.” “This appliance is equipped at the factory for use with natural gas only. Units using propane must be field converted using the LP conversion kit, Cat. No. H0920.
FINAL INSPECTION BY:
ANSI Z21.88-2002 CSA 2.33-2002 CAN/CGA 2.17-M91 VENTED GAS FIREPLACE HEATER FOYERA AU GAZ CHAUFFANT AVEC EVACUATION P/N 9-1467A SERIAL NUMBER/NOMBRE DE SERIE
XXX XXX
IIIIIIIIIIIIIIIIIIII
XXX
P/N 9-1467A
MANTEAU DU DESSUS DE L'APPAREIL
DEPTH
(MAX)