FIREPLACE SPECIFICATIONS
Cat. No. H3427
Model:
Description: Merit Plus Electric Fireplace, 33” Radiant
Shipping Weight: 81 lb.'s (36.75 KG) Packaging:
41” x 17 3/4” x 33 1/2”
(1040 mm x 451 mm x 850 mm)
14.1cu. ft.
Power Requirements: (120 Volt, 60 Hz.)
Rated Wattage - 1600 Watts Amperage - 13.33 Amps
(240 Volt, 60 Hz.)
Rated Wattage - 3000 Watts Amperage - 12.5 Amps
Blower CFM: 83 CFM
(120 V): 5,461 BTU/HR
(240 V): 10,239 BTU/HR
MINIMUM CLEARANCES TO COMBUSTIBLES
This appliance is an electric fireplace designed to be framed in with combustible materials (up to the edge of the appliance). A drywall lip at the top of the fireplace and 4 nailing flanges on the sides of the appliance is provided to facilitate installation.
| Clearances | |
|
|
|
Sides |
| 0 inches - 0 mm |
Floor |
| 0 inches - 0 mm |
Top |
| 0 inches - 0 mm |
Table 2 |
|
|
|
|
|
Mantel Clearance: Combustible and
Hearth Protection: A hearth is not mandatory, but it is recommended for aesthetic purposes. Secure the hearth extension to the floor to prevent possible shifting. Do no block the air- flow beneath the appliance (read the following WARNING).
Before You Start
Check appliance for any concealed damage.
DETAILED INSTALLATION STEPS
1.Complete the framing opening to the dimen- sions specified in Figure 2.
2.Prepare the connections to power source: 120 Volt Connections - Locate the power cord on the left side of the unit and connect it to the outlet installed during the framing (see Figure 2). Verify that the power to the receptacle is off.
Hard wired installation:
Ensure that there is a minimum of 8" of the service cable for connection to the junction box on the fireplace.
-Loosen four screws to remove the junction box cover plate.
-Disconnect and remove the 120 Volt power cord from the fireplace wires.
-Position the fireplace into the
-Complete the wiring to the fireplace as shown on Page 10.
-Place all wire connectors inside the junction box.
-Attach junction box cover plate with four screws.
240 Volt Connections - Ensure that there is a minimum of 8" of the service cable for connection to the junction box on the fireplace.
-Loosen four screws to remove the junction box cover plate.
-Disconnect and remove the 120 Volt power cord from the fireplace wires.
-Position the fireplace into the
-Complete the wiring to the fireplace as shown on Page 11.
-Place all wire connectors inside the junction box.
-Attach junction box cover plate with four screws.
The fireplace wires L1, L2, N, N1, N2 and G are attached to the rear of the junction box cable clamp for easy access.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3.Wire a dedicated, properly fused circuit with an Amp rating for the appropriate voltage (120 V - 15 Amps or 240 V - 20 Amps). A dedicated circuit is required to prevent overloading a house circuit in cases of having multiple appliances on the same circuit. Use an outlet that is protected by a ground fault circuit interrupter where required by electrical code.
4.(If applicable) Make wall mount wall switch or wall thermostat connections as outlined on Pages 11 & 12.
5.Perform a function test. See Manual Control Panel Operation on Page 6 and Remote Control Operation on Page 7.
ELECTRICAL CONNECTIONS
Refer to the electrical diagrams on Pages 10 to 14.
WARNING
Electrical wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electrical shock and injury to individuals.
IMPORTANT
Any electrical
WARNING
Do not use this fireplace if any part of it has been underwater. Immediately call a qualified service technician to inspect the fireplace and replace any part of the electrical system which has been under water.
5