28.0 POSITIONING OF FIELD REMOVABLE PARTS
WARNING
Failure to position the parts in
accordance with these diagrams
or failure to use only parts specifi-
cally approved with this heater
may result in property damage
or personal injury.
Figure 13
4 off burner
installation
positions
Figure 11
Removal and refitting of glass door
assembly and burner assembly.
Visual check for cor-
rect pilot flame.
The glass panel is
supported by two
self-locking M6
screws, one on
each side
Damper
Fixing
hole
Removal and refitting of the decora-
tive glass facia (see Section 17.0)
Glass Door Removal: Remove
the four (4) screws indicated,
then lift door off.