Hardware Tests

The following Hardware Tests can be selected from this menu:

LCD Test

Button Test

DRAM Memory Test

ROM Memory Test

Parallel Wrap (if available)

Serial Wrap (if available)

Serial 1 Wrap (if available)

Serial 3 Wrap (if available)

LCD Test

To run the LCD Test:

1.Select LCD Test from the Diagnostic menu.

The LCD test continually executes the LCD display test.

2.Press Return/Stop to cancel the test.

Button Test

To run the Button Test:

1.Select Button Test from the Diagnostic menu.

With no buttons pressed several OP (Open) appear on the display.

2.Press each button one at a time and a CL (Closed) displays in place of an OP. The proper operation of each button can be checked.

3.Press Return/Stop to cancel the test.